Water Softener Filter Change Signal; Dose Deviation Screen; Lower Counter Alarm Limit Screen - La San Marco TOP 85 Emploi Et Entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10.11 Number of service intervention cycles screen
Screen 27
SERVICE
100000 CYCLES

10.12 Water softener filter change signal

Screen 28
CHANGE WATER
10000 LITRES

10.13 Dose deviation screen

Screen 40
DOSE DEVIATION

10.14 Lower counter alarm limit screen

Screen 41
FLOW METER LIMIT
62
Service intervention cycle number technical level program-
ming screen.
This technical level programming screen is used to set the number
of cycles after which the intervention of technical service is shown
on the display.
Change the number using the + / - buttons from a value of 0 to
100000 in steps of 1000. If the set value is 0, the signal is disabled
Default setting: 0 (function disabled)
Press NEXT to go to the next screen.
If no button is selected within 30 seconds, the machine ready screen
will appear automatically (screen 2).
Pressing ESC returns to the machine ready screen (screen 2).
Water softener filter change signal warning setting technical
level programming screen.
This technical level programming screen is used to set the number of
litres after which the need to replace the water softener filter is shown
on the display.
This screen will not be displayed if the water counter was not enabled
on screen 43.
Change the number using the + / - buttons from a value of 0 to 15000
in steps of 100. If the set value is 0, the signal is disabled.
Default setting: 0 (function disabled)
Press NEXT to go to the next screen.
If no button is selected within 30 seconds, the machine ready screen
will appear automatically (screen 2).
Pressing ESC returns to the machine ready screen (screen 2).
Dose deviation technical level programming screen.
The following screen shows the deviation parameter from the pro-
grammed dose by means of self-learning.
Change the number using the + / - buttons from a value of 10 to 70
in steps of 1.
Default setting: 60%
The signal can be disabled by pressing the + button until Off appears.
Press Ok to confirm the change
Press NEXT to go to the next screen.
If no button is selected within 30 seconds, the machine ready screen
will appear automatically (screen 2).
Pressing ESC returns to the machine ready screen (screen 2).
lower counter alarm limit programming screen.
The following screen is used to program the lower limit parameter
for the quantity in ml per seconds for all counters, under which the
counter alarm is indicated.
Change the number using the + / - buttons from a value of 0.1 to 1 in
steps of 0.1.
Default setting : 0.5
Press NEXT to go to the next screen (29).
If no button is selected within 30 seconds, the machine ready screen
will appear automatically (screen 2).
Pressing ESC returns to the machine ready screen (screen 2).

Publicité

Table des Matières
loading

Table des Matières