Description des paramètres
13-43 Logic Rule Operator 2
Option:
4
4
[0]
Disabled
*
[1]
AND
[2]
OR
[3]
AND NOT
[4]
OR NOT
[5]
NOT AND
[6]
NOT OR
[7]
NOT AND
NOT
[8]
NOT OR NOT
13-44 Logic Rule Boolean 3
Option:
[0]
False
*
[1]
True
[2]
Running
[3]
In range
[4]
On reference
[7]
Out of current range
[8]
Below I low
[9]
Above I high
[16] Thermal warning
[17] Mains out of range
[18] Reversing
[19] Warning
[20] Alarm (trip)
[21] Alarm (trip lock)
[22] Comparator 0
[23] Comparator 1
84
®
VLT
Fonction:
paramétre 13-42 Logic Rule Boolean 2, et
l'entrée booléenne du paramétre 13-42 Logic
Rule Boolean 2. Le Paramétre 13-42 Logic Rule
Boolean 2 correspond à l'entrée booléenne
du paramétre 13-44 Logic Rule Boolean 3. Le
Paramétre 13-40 Logic Rule Boolean 1 et le
paramétre 13-42 Logic Rule Boolean 2 corres-
pondent à l'entrée booléenne calculée aux
paramétre 13-40 Logic Rule Boolean 1,
paramétre 13-41 Logic Rule Operator 1 et
paramétre 13-42 Logic Rule Boolean 2.
Ignore le paramétre 13-44 Logic Rule Boolean
3.
Fonction:
Sélectionner la troisième entrée
booléenne (VRAI ou FAUX) pour la
règle logique sélectionnée. Voir le
paramétre 13-40 Logic Rule Boolean 1,
le paramétre 13-41 Logic Rule Operator
1 et le paramétre 13-42 Logic Rule
Boolean 2 et l'entrée booléenne. Voir
le paramétre 13-01 Start Event ([0]-
[61]) et le paramétre 13-02 Stop Event
([70]-[74]) pour une description
détaillée.
Danfoss A/S © 07/2016 Tous droits réservés.
Midi Drive FC 280
13-44 Logic Rule Boolean 3
Option:
[24] Comparator 2
[25] Comparator 3
[26] Logic rule 0
[27] Logic rule 1
[28] Logic rule 2
[29] Logic rule 3
[30] SL Time-out 0
[31] SL Time-out 1
[32] SL Time-out 2
[33] Digital input DI18
[34] Digital input DI19
[35] Digital input DI27
[36] Digital input DI29
[39] Start command
[40] Drive stopped
[42] Auto Reset Trip
[50] Comparator 4
[51] Comparator 5
[60] Logic rule 4
[61] Logic rule 5
[70] SL Time-out 3
[71] SL Time-out 4
[72] SL Time-out 5
[73] SL Time-out 6
[74] SL Time-out 7
[83] Broken Belt
13-51 SL Controller Event
Option:
[0]
False
*
[1]
True
[2]
Running
[3]
In range
[4]
On reference
[7]
Out of current range
[8]
Below I low
[9]
Above I high
[16] Thermal warning
[17] Mains out of range
[18] Reversing
[19] Warning
Fonction:
Fonction:
Sélectionner la troisième entrée
booléenne (VRAI ou FAUX) pour la
règle logique sélectionnée. Voir le
paramétre 13-40 Logic Rule Boolean 1,
le paramétre 13-41 Logic Rule Operator
1, le paramétre 13-42 Logic Rule
Boolean 2 et l'entrée booléenne. Voir
le paramétre 13-01 Start Event ([0]-
[61]) et le paramétre 13-02 Stop Event
([70]-[74]) pour une description
détaillée.