Description des paramètres
13-40 Logic Rule Boolean 1
Option:
Fonction:
[27] Logic rule 1
[28] Logic rule 2
[29] Logic rule 3
[30] SL Time-out 0
[31] SL Time-out 1
[32] SL Time-out 2
[33] Digital input DI18
[34] Digital input DI19
[35] Digital input DI27
[36] Digital input DI29
[39] Start command
[40] Drive stopped
[42] Auto Reset Trip
[50] Comparator 4
[51] Comparator 5
[60] Logic rule 4
[61] Logic rule 5
[70] SL Time-out 3
[71] SL Time-out 4
[72] SL Time-out 5
[73] SL Time-out 6
[74] SL Time-out 7
[83] Broken Belt
13-41 Logic Rule Operator 1
Option:
Fonction:
Sélectionner le premier opérateur logique à
utiliser sur les entrées booléennes à partir
des paramétre 13-40 Logic Rule Boolean 1 et
paramétre 13-42 Logic Rule Boolean 2.
[0]
Disabled
Ignore les paramétre 13-42 Logic Rule Boolean
*
2, paramétre 13-43 Logic Rule Operator 2 et
paramétre 13-44 Logic Rule Boolean 3.
[1]
AND
Évalue l'expression [13-40] ET [13-42].
[2]
OR
Évalue l'expression [13-40] OU [13-42].
[3]
AND NOT
Évalue l'expression [13-40] ET PAS [13-42].
[4]
OR NOT
Évalue l'expression [13-40] OU PAS [13-42].
[5]
NOT AND
Évalue l'expression NON [13-40] ET [13-42].
[6]
NOT OR
Évalue l'expression NON [13-40] OU [13-42].
[7]
NOT AND
Évalue l'expression PAS [13-40] ET PAS
NOT
[13-42].
[8]
NOT OR NOT Évalue l'expression PAS [13-40] OU PAS
[13-42].
13-42 Logic Rule Boolean 2
Option:
Fonction:
Sélectionner la deuxième entrée
booléenne (VRAI ou FAUX) pour la
règle logique sélectionnée. Voir le
MG07C304
Guide de programmation
13-42 Logic Rule Boolean 2
Option:
[0]
False
*
[1]
True
[2]
Running
[3]
In range
[4]
On reference
[7]
Out of current range
[8]
Below I low
[9]
Above I high
[16] Thermal warning
[17] Mains out of range
[18] Reversing
[19] Warning
[20] Alarm (trip)
[21] Alarm (trip lock)
[22] Comparator 0
[23] Comparator 1
[24] Comparator 2
[25] Comparator 3
[26] Logic rule 0
[27] Logic rule 1
[28] Logic rule 2
[29] Logic rule 3
[30] SL Time-out 0
[31] SL Time-out 1
[32] SL Time-out 2
[33] Digital input DI18
[34] Digital input DI19
[35] Digital input DI27
[36] Digital input DI29
[39] Start command
[40] Drive stopped
[42] Auto Reset Trip
[50] Comparator 4
[51] Comparator 5
[60] Logic rule 4
[61] Logic rule 5
[70] SL Time-out 3
[71] SL Time-out 4
[72] SL Time-out 5
[73] SL Time-out 6
[74] SL Time-out 7
[83] Broken Belt
13-43 Logic Rule Operator 2
Option:
Danfoss A/S © 07/2016 Tous droits réservés.
Fonction:
paramétre 13-01 Start Event ([0]-[61])
et le paramétre 13-02 Stop Event ([70]-
[74]) pour une description détaillée.
Fonction:
Sélectionner le deuxième opérateur logique
à utiliser sur l'entrée booléenne calculée aux
paramétre 13-40 Logic Rule Boolean 1,
paramétre 13-41 Logic Rule Operator 1 et
4