Télécharger Imprimer la page

Technical Data - Bosch Rexroth PL6-PQI Manuel D'utilisation

Publicité

4/12
Bosch Rexroth AG Hydraulics
Technical data (For applications outside these parameters, please consult us!)
Supply voltage
U
at z2 – b2
B
Smoothing capacitor, separately
at z2 – b2
Valve solenoid, max.
Current consumption, max.
Power consumption (typical)
Input signal (command value)
Input signal (command value p)
Actual value from the pressure sensor
Pressure controller OFF
External enquiry pressure controller active z24: 24 V/0.1 A max.
Signal source
Enable output stage
Position
Supply
transducer
Signal pilot control valve
Signal cam
Solenoid output
b6 – b8
Cable lengths between amplifier and valve Solenoid cable:
Special features
LED displays
Nominal 24 V =
Battery voltage 21...40 V,
Rectified alternating voltage U
(one-phase, full-wave rectifier)
Recommendation: Capacitor module VT 11110 (see data sheet 30750)
(only necessary if the ripple of U
A/VA 2.7/40 (size 6)
A 1.7
The current consumption may increase with min. U
and extreme cable length to the control solenoid
W 37
b20: 0...±10 V
Differential amplifier
z20: 0...±10 V
(R
= 100 kΩ )
i
z12: 0...10 V
Differential amplifier
z10: 0 V
z14: 4...20 mA Current input
b16: 0...+10 V/1...+6 V Voltage input
b18: 0 V Reference
b10: 6...40 V =
Potentiometer 10 kΩ
Supply with ±10 V from b32, z32 (10 mA) or external signal source
At z16, U = 8.5...40 V, R
b30: –15 V (25 mA)
z30: +15 V (35 mA)
b22: 0...±10 V, R
= 10 kΩ/Ref. b24
L
b26: 0...±10 V, R
= 10 kΩ/Ref. b28
L
Clocked current controller
I
2.7 A
max
up to 20 m 1.5 mm
20 to 60 m 2.5 mm
Position transducer: 4 x 0.5 mm
Pressure sensor:
4 x 0.5 mm
Cable break protection for actual value cable,
Position control with PID behavior,
Pulsed output stage,
Fast energization and fast deletion for short actuating times,
Short-circuit-proof outputs,
Controller switch-off,
Cable break monitoring for pressure sensor,
Leakage oil compensation
green:
Enable
yellow: Cable break position transducer
red:
Supply voltage (U
yellow: Pressure controller OFF
yellow: Pressure controller is working
both yellow LEDs are flashing: Cable break pressure sensor
VT-VPRAP1-540-1X/.../SI RE 30082/06.12
= 21...28 V
eff
> 10 %)
B
B
= 100 kΩ, LED (green) on front plate lights up
i
2
2
2
(shielded)
2
(shielded)
too low)
B

Publicité

Chapitres

loading