Télécharger Imprimer la page

Bosch Rexroth PL6-PQI Manuel D'utilisation page 31

Publicité

2/12
Bosch Rexroth AG Hydraulics
Ordering code, accessories
Hydraulic component
(control)
Axis control
Valve type
High-response valve
Control
Analog
Function
p/Q control
Preferred types
Amplifier type
VT-VACAP-500-20/V0
VT-VACAP-500-20/V0/2CH
Suitable card holder:
– Open card holder VT 3002-1-2X/32F
(see data sheet 29928).
Only for control cabinet installation!
Front plate
Flow preselection
Pressure controller off
Controller is working
Amplification p signal +10 %/–20 %
Pressure zero point ±10 %
Test point p
VT V
A
C
A
= A
= C
= A
= P
Material number
0811405157
0811405158
Zero point flow
Adjustment K
P
Adjustment K
I
Adjustment K
D
0...10 V
actual
Test point 0 V
VT-VACAP-500-2X/V0/... RE 30134/06.12
P
500 2X V0
no code =
2CH =
V0 =
2X =
500 =
Standard variant without valve amplifier function
For high-response valves
All valve types with installed electronics
1 and 2 with 0811405157
1 only with 0811405158
1
2
Q
max
Q=0
+
+
K
P
Regler
off
K
I
ON
K
D
P
ist
P
null
+
+
P
ist
0 V
1 channel
2 channels
Customer version
Catalog version
Component series 20 to 29
(20 to 29: Unchanged technical data
and pin assignment)
Serial number for types
Option

Publicité

Chapitres

loading