Technical Data - Bosch Rexroth LTU350/1 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 29
3 609 929 B47/2008-12 | LTU350/1
15

Technical data

Table 8
Designation
Order number
Input voltages
Intermediate circuit voltage
Control voltage
Output voltage
Output frequency
Rated current/peak current
Maximum line length to motor
Interference suppression
Interference immunity
Permissible ambient temperature
Admissible relative humidity during operation 20 % - 90 % non-condensing
Admissible storage temperature
Admissible relative storage humidity
Protection class
Protection type
Dimensions (W x H x D)
Weight
LTU350/1
0 608 750 111
From the supply module
160 V
to 320 V
DC
DC
+ 24 V / – 24 V / 5 V (SELV)
3-phase, 0-230 V
AC
0 Hz to 1000 Hz
Depending on the connected motor, max. 12 A / 50 A
100 m
EN 55011 class A (industrial area)
IEC 1000-4 part 2 to part 5 severity level 4
0 to 55 °C with fan
–20 °C to 70 °C
20 - 95 %
Protection class I
IP20 (protection against accidental contacts) when in-
stalled
46 mm x 271 mm x 285 mm
2.85 kg
Bosch Rexroth AG
27/84

Publicité

Table des Matières
loading

Table des Matières