o) Resistance Measuring
• Move the setting wheel (7) to the icon for resistance measurement, see figure
on the right.
Make sure that all circuit parts, circuits and components and other objects of
measurement are disconnected from the voltage and discharged.
• Connect the measuring lines to the current injection probe.
• Check the measuring lines for continuity before measurement. Connect the two
measuring prods for this. The resistance value indicated in the LC display must be
approximately 0.5 Ω (inherent resistance of the measuring lines).
• Now connect the measuring lines to the object to be measured.
• If "OL" appears on the display, you have exceeded the measuring range or the
measuring circuit is interrupted.
• Remove the measuring lines from the object to be measured after the measurement and
switch off the current injection probe. For this, turn the setting wheel (7) into the position
"OFF".