8. Installation

Assembly and installation of the device must be carried out by a specialist familiar with the
hazards and the relevant regulations. Maintenance, operation and commissioning of this device
must only be carried out by qualified persons.
When choosing a location for your device, make sure to avoid impact, vibration, dust, extreme
heat (>+45 °C) and cold (<-30 °C). Furthermore, no powerful transformers or motors must be used
close to the device.
Never cover the device. Make sure when mounting with other equipment that there is sufficient
ventilation. Maintain a sufficient distance to other devices and walls. Never install the effect
light in direct proximity of heat sources. Do not point any strong spotlights or light sources
towards the device. This may cause overheating (danger of fire!).
Do not drill or screw additional screws into the casing in order to fasten the device. This may
expose dangerous voltage to touch.
The device must be mounted out of normal reach.
Illuminated objects must be at least 0.5 m away from the device's light emission source. Easily
flammable materials such as decorative fabrics must also have a distance of at least 0.5 m to the
device. Otherwise, such objects may catch fire!
When mounting the product, make sure that the power cord is neither jammed nor damaged by
sharp edges.
During installation or service work, the area below the place of installation must be cordoned
off.
The installation surface or mounting fixture needs to be designed in a way that it can take
10 times its load capacity for at least 1 hour without permanent damaging deformation.
It is also essential that the device is secured by means of a second safety restraint that is inde-
pendent of the actual mounting supports when installing it in an elevated position. No part of
the installation must fall down if the main suspension system fails.
Observe all relevant regulations of your country when installing the device.
Acceptance test (in case of industrial/public use):
Before first use and after any significant modifications, the installation (including the electrical
connections) must be inspected by an official expert.
A yearly inspection by an expert is required.
• Install the effect beamer on the ceiling, the wall or a suitable crossbeam with the mounting angles. The
assembly must never swing freely. Use assembly material suitable for the assembly area and for bear-
ing the effect light load.
• When set up in an elevated position, secure the device with an additional suitable safety restraint cable
or safety net. The safety retention rope or the net must be designed to support the effect light in the event
of failure of the main support system independently of the main attachment.
• Set the desired inclination angle and tighten the thumb screws to the assembly angles well.
27