5) Service
a) Have your power tool serviced by a qualified repair person using only
identical replacement parts. This will ensure that the safety of the power tool
is maintained.
Safety Instructions for Electrical Filling and Flushing Unit
WARNING
Read all safety warnings and all instructions. Failure to follow the warnings and
instructions may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
● Do not use the electrical device if it is damaged. There is a danger of accident.
● Only connect the power tool to an outlet with a functioning protected earth.
● Examine the hoses and seals for damage every time before using. Damaged
hoses can burst and cause injury.
● Only use original hoses, fittings and couplings for the electrical device.
This ensures that the safety of the electrical device is maintained.
● Apply the electrical device horizontally and dry for operation. Penetration
of water into the electrical device increases the risk of electric shock.
● Do not aim liquid jets at the electrical device, not even for cleaning.
Penetration of water into the electrical device increases the risk of electric shock.
● Do not suck up inflammable or explosive liquids, for example petrol, oil,
alcohol, solvent, with the power tool. The fumes or liquids can ignite or explode.
● Do not operate the electrical device in rooms where there is a risk of explo-
sion. The fumes or liquids can ignite or explode.
● Protect the electrical device against frost. The electrical device could be
damaged. Empty the pump body, the plastic tank and the hoses of the electrical
device.
● Never let the electrical device operate unattended. Switch the electrical
device off at the On/Off switch (5) and pull out the mains plug for longer
work breaks. Electrical devices can cause hazards which lead to material damage
or injury when left unattended.
● Do not operate the electrical device on a closed pipe system for a prolonged
period of time. The electrical device could be damaged by overheating.
● Children and persons who, due to their physical, sensory or mental abilities
or lack of experience and knowledge are unable to operate the electrical
device safely may not use this electrical device without supervision or
instruction by a responsible person. Otherwise there is a risk of operating
errors and injuries.
● Only allow trained persons to use the electrical device. Apprentices may only
operate the electrical device when they are older than 16, when this is necessary
for their training and under the supervision of a trained operative.
● Check the power cable of the electrical device and the extension leads
regularly for damage. Have these renewed by qualified experts or an authorised
REMS customer service workshop in case of damage.
● Only use approved and appropriately marked extension leads with a suffi-
cient cable cross-section. Use extension leads up to a length of 10 m with
cable cross­section 1.5 mm², from 10 – 30 m with cable cross­section 2.5 mm².
Explanation of symbols
WARNING
Danger with a medium degree of risk which could result in
death or severe injury (irreversible) if not heeded.
CAUTION
Danger with a low degree of risk which could result in minor
injury (reversible) if not heeded.
NOTICE
Material damage, no safety note! No danger of injury.
Read the operating manual before starting
Power tool complies with protection class I
Environmentally friendly disposal
CE conformity mark

1. Technical data

Use for the intended purpose
WARNING
Only use the REMS Solar-Push for the intended purpose, namely filling, flushing
and bleeding solar systems, geothermal systems and underfloor heating and for
filling tanks. Permissible media: heat transfer liquids, antifreeze, water, aqueous
solutions, emulsions.
All other uses are not for the intended purpose and are prohibited.
1.1. Scope of Supply
Electrical filling and flushing unit, 2 flexible, fabric hoses, instruction manual
1.2. Article numbers
REMS Solar-Push K 60
REMS Solar-Push I 80
PVC fabric hose ½" T60
EPDM fabric hose ½" T100
EPDM fabric hose ½" T165
30 l plastic tank
Pressure relief valve
Fine filter with filter cartridge 50 μm
Fine filter cartridge 50 μm
Fine filter with fine filter bag 70 μm
Fine filter bag 70 μm (10 bags)
Adapter for canister lid
Shut-off valve ¾"
Changeover valve
Changeover valve flow direction
REMS CleanM
1.3. Applications
Plastic tank volume
Transport capacity at
40 m pumping head
Transport pressure
Temperature of the transpor-
ted media (constant load)
pH value of the
transported media
1.4. Electrical data
Protection class
Type of protection
1.5. Dimensions
L × W × H
1.6. Weights
with PVC fabric hoses
with EPDM fabric hoses
1.7. Noise information
Workplace-related
emissions value
1.8. Vibrations
Weighted effective value
of the acceleration
The indicated weighted effective value of acceleration has been measured
against standard test procedures and can be used by way of comparison with
another device. The indicated weighted effective value of acceleration can also
be used as a preliminary evaluation of the exposure.
CAUTION
The indicated weighted effective value of acceleration can differ during opera-
tion from the indicated value, dependent on the manner in which the device is
used. Dependent upon the actual conditions of use (periodic duty) it may be
necessary to establish safety precautions for the protection of the operator.
1.8. Suction and pressure hoses
Hose length
Hose size
Hose connector, both sides
Temperature resistance
2. Start-up
2.1. Electrical connection
WARNING
Caution: Mains voltage present! Before connecting the electrical filling and
flushing unit, check whether the voltage given on the rating plate corresponds
to the mains voltage. Only use sockets/extension leads with a functioning
protected earth contact. On building sites, in a wet environment, indoors and
outdoors or under similar installation conditions, only operate the electric filling
and flushing unit on the mains with a fault current protection switch (FI switch)
which interrupts the power supply as soon as the leakage current to earth
exceeds 30 mA for 200 ms.
2.2. Connecting the electrical filling and flushing unit to the solar system
Connect one of the two fabric hoses to the pressure line connection (1). Connect
the 2nd fabric hose to the return line connection (2) of the plastic tank (3).
Connect the respective free end of the pressure or return line to the ball valves
of the solar system and open the ball valves. Close the connecting valve between
the two ball valves of the solar system. Fill the plastic tank (3) with transported
115302
medium and open the ball valve (4). Plug the mains plug of the electrical filling
115301
and flushing unit into the socket with a protective earth.
115314
CAUTION
115315
115319
Danger of injury due to escaping transported medium. Tighten the hose
115375
screw connections and check for leaks regularly.
Solar-Push I 80
Solar-Push K 60
30 l
30 l
18 l/min
16 l/min
< 6.5 bar/0.65 MPa/
< 5 bar/0.55 MPa/
94 psi
80 psi
≤ 80°C
≤ 60°C
7 – 8
7 – 8
230 V 1~; 50 Hz;
230 V 1~; 50 Hz;
1000 W
860 W
110 V 1~; 50 Hz;
860 W
I
I
IP 55
IP 44
550 × 480 × 970 mm
550 × 480 × 970 mm
(21.7" × 18.9" × 38.3") (21.7" × 18.9" × 38.3")
20.4 kg (45 lb)
19.8 kg (43.7 lb)
20.0 kg (44.2 lb)
19,4 kg (42.9 lb)
Solar-Push I 80
Solar-Push K 60
73 dB (A)
70 dB (A)
2.5 m/s²
2.5 m/s²
PVC-
EPDM-
EPDM-
fabric
fabric
fabric
hose T60
hose T100 hose T165
3 m
3 m
3 m
½"
½"
½"
¾"
¾"
¾"
≤ 60°C
≤ 100°C
≤ 165°C
eng
115217
115323
043052
115220
115221
115379
115324
115325
115326
140119

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Solar-push k 60115302115301

Table des Matières