Manufacturer's Warranty; Spare Parts Lists - REMS Solar-Push I 80 Notice D'utilisation

Masquer les pouces Voir aussi pour Solar-Push I 80:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
eng
5. Faults
WARNING
Switch off the On/Off switch and pull out the mains plug before repairing the fault on the electrical filling and flushing unit.
5.1. Fault: Pump does not suck up or is not working.
Cause:
● Unsuitable transport medium.
● Leaking suction pipe.
● Suction pipe or fine filter blocked.
● Pressure hose is blocked.
● Ball valve (4) is closed.
● The plastic tank (3) is empty.
● Air in the pump (only in Solar-Push K 60).
● Pump has seized (only in Solar-Push K 60).
● Power cable defective.
● Pump/motor defective.
5.2. Fault: Pump builds up no pressure or does not transport the medium.
Cause:
● Transport height exceeded.
● Unsuitable transport medium.
● Ball valves/solar unit connecting valve not opened/closed correctly.
● Fine filter blocked.
● Pump/motor defective.
5.3. Fault: Liquid escapes from the pump.
Cause:
● Seals of the pump connections are defective.
● Pump seals are defective.
6. Disposal
The electrical filling and flushing unit may not be thrown in the domestic waste
after use. It must be disposed of properly by law.

7. Manufacturer's Warranty

The warranty period shall be 12 months from delivery of the new product to the
first user. The date of delivery shall be documented by the submission of the
original purchase documents, which must include the date of purchase and the
designation of the product. All functional defects occurring within the warranty
period, which are clearly the consequence of defects in production or materials,
will be remedied free of charge. The remedy of defects shall not extend or
renew the warranty period for the product. Damage attributable to natural wear
and tear, incorrect treatment or misuse, failure to observe the operational
instructions, unsuitable operating materials, excessive demand, use for unau-
thorized purposes, interventions by the customer or a third party or other
reasons, for which REMS is not responsible, shall be excluded from the warranty
Services under the warranty may only be provided by customer service stations
authorized for this purpose by REMS. Complaints will only be accepted if the
product is returned to a customer service station authorized by REMS without
prior interference in an unassembled condition. Replaced products and parts
shall become the property of REMS.
The user shall be responsible for the cost of shipping and returning the product.
The legal rights of the user, in particular the right to make claims against the
seller under the warranty terms, shall not be affected. This manufacturer's
warranty only applies for new products which are purchased in the European
Union, in Norway or in Switzerland.
This warranty is subject to German law with the exclusion of the United Nations
Convention on Contracts for the International Sales of Goods (CISG).

8. Spare parts lists

For spare parts lists, see www.rems.de → Downloads → Parts lists.
Remedy:
● Only use approved transport media (see 1. Intended Use and 1.3.).
● Change seal/suction pipe.
● Clear the blockage in the suction pipe. Clean file filter7filter screen (see 4.1.) or
change filter screen.
● Clear the blockage in the pressure hose.
● Open ball valve.
● Fill or refill the plastic tank with transport medium (see 3. Operation).
● Fill liquid into pump (see 3. Operation).
● Push a flat screwdriver through the middle hole in the motor fan cover and
release the blockage by turning abruptly to the left and right several times.
● Have the power cable changed by qualified personnel or an authorised REMS
customer service workshop.
● Have the pump/motor checked/repaired by an authorised REMS customer
service workshop.
Remedy:
● Check transport height (see 1.3.).
● Only use approved transport media (see 1. Intended Use and 1.3.).
● Open/closed ball valves according to 2.2.
● Clean the fine filter/filter screen (see 4.1.) or change the filter screen.
● Have the pump/motor checked/repaired by an authorised REMS customer
service workshop.
Remedy:
● Change seals.
● Have the pump checked/repaired by an authorised REMS customer service
workshop.
eng

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Solar-push k 60115302115301

Table des Matières