6.5 Installation of the version
with double filter for air renewal
During installation pay attention to the
orientation of the air inlet filter fins.
OUT
Fig. 4
To guarantee weatherproof protection, install the
housing on the support following the inclination
limits as shown in the picture.
Depending on the angle of inclination of the housing,
the orientation of the filter fins must prevent water
penetrating in case of rain:
Fig. 5
Maximum tilt of the transversal axis: 0°.
Maximum tilt of the longitudinal axis: ±45°.

6.6 Desiccant bag

Take the dessicant salt bag out of its pack and insert it
into the product.
8
6.7 Replacement of the
germanium window
Unscrew the front window fastening screws using the
hexagonal wrench included in the supply. Remove
the window and position the replacement part,
making sure the seal remains in its seat. Replace the
housing and fasten in place using the previously
removed fastening screws.