Appendix B: Using Amiq-Srl Modules - Avocent AMX Série Guide D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

54
AMX Switch Series Installer/User Guide

Appendix B: Using AMIQ-SRL Modules

The AMIQ-SRL module is a serial-to-VGA converter which permits VT100-capable devices to be
viewed from the AMX switch local port. The actual serial data is not accessed, but is merely
displayed. All serial data coming from the target device is displayed in a VT100 window, placed
into a video buffer and sent to the AMX switch as though it came from a VGA server. Likewise,
keystrokes entered on a keyboard are sent to the attached device as though they were typed on a
VT100 terminal.
AMIQ-SRL module modes
The following modes can be accessed from the AMIQ-SRL module:
On-Line: This mode enables you to send and receive serial data.
History: This mode enables you to review serial data.
Configuration: This mode enables you to specify communication parameters, the appearance
of the serial data, key combinations for specific actions and macros.
Configuring the AMIQ-SRL module
NOTE: The AMIQ-SRL module is a DCE device and only supports VT100 terminal emulation.
Pressing
Ctrl-F8
to configure your AMIQ-SRL module.
NOTE: When the Configuration Screen is active, pressing Enter saves changes and returns you to the previous
screen. Pressing Esc returns you to the previous screen without saving changes.
Within the Configuration Screen, you can modify the following options:
Baud Rate: This option allows you to specify the serial port communications speed in bauds
per second (BPS). Available options are 300, 1200, 2400, 9600, 19200, 34800, 57600 or
115200. The default value is 9600.
Parity: This option allows you to specify the serial port communications parity. Available
options are EVEN, ODD or NONE. The default value is NONE.
Flow Control: This option allows you to specify the type of serial flow control. Available
options are NONE, XOn/XOff (software) and RTS/CTS (hardware). The default value is
NONE. If you select a Baud Rate of 115200, the only available Flow Control is
RTS/CTS (hardware).
AMX/CD Mode: This option allows you to control how the AMX switch and CD lines
operate. Available options are Always on and Toggle. When in Toggle mode, the AMX switch
and CD lines are turned off for one-half second and then turned on each time a module is
selected or deselected. The default value is Always on.
Enter Sends: This option enables you to specify the keys that are transmitted when
pressed. Available options are <CR> (Enter) or <CR><LF> (Enter
will activate the Configuration Screen, which contains menu items that allow you
is
Enter
Linefeed).
-

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Amx5000Amx5010Amx5110Amx5100Amx5120

Table des Matières