CONTROL PANEL

DISPLAY
ON/OFF
DISPLAY
MENU
Once the self-diagnosis is complete, the display will
show the following information:
UNIT ON 00 HRS
INLET 00°F / INLET 00%
The first line of the display shows the total number of
hours the unit has been in operation. This value may be
reset to zero to track job hours (see "Job Hours Reset"
below). The second line of the display alternates
between inlet temperature and inlet humidity.
User settings menu
A number of settings may be changed by the user.
System information is also available. These items are
accessed by pressing the
press of the key will display the next parameter (see list
below). When you reach the parameter you wish to
adjust, press the
MENU SELECTON key to increase
the value. Press
DISPLAY MENU again to accept the
setting and re-start the display cycle. If no keys are
selected for 20 seconds the display will automatically
reset and return to the normal display mode.
Note that only menu items followed by a greater-than
symbol ( > ) may be adjusted.
JOB HOURS
RESET? >
Press
to reset hours to zero. NOTE: When in
Humidistat mode, the unit will display HUMIDISTAT on
the top line during normal operation rather than JOB
HOURS.
LIFE HOURS
00 HRS
Shows total unit operating hours. Value cannot be
modified.
07-01674J F410, F411
PURGE PUMP
MENU
SELECTION /
UP KEY
DISPLAY MENU key. Each
INLET
00° 00%
Shows current temperature and RH of inlet and outlet.
HUMIDISTAT MODE
ON/OFF >
In ON mode, unit will maintain the humidistat setpoint
(see below). Press
NOTE: When in Humidistat mode, the unit will display
HUMIDISTAT on the top line during normal operation
rather than JOB HOURS.
HUMIDISTAT
SETPOINT 00% >
Sets humidity level when unit is in Humidistat Mode (see
above). Press
to change RH value at 5% increments.
Settings cycle upward through 90%RH and start again at
30%RH.
TEMP UNITS
F° >
Shows current temperature scale. Press
Fahrenheit or Centigrade scale.
LANGUAGE
ENGLISH >
Shows current display panel language. Press
select Spanish, German, French or English.
COIL TEMP
00°F
Displays the cold (evaporator) coil temperature.
SENSOR ID >
00000000
This function not in use. Press
following values: SENSOR TYPE, SENSOR REVISION,
and SENSOR CONF REV. A Dri-Eaz service technician
may ask you for these values when diagnosing a
problem.
COMPRSSR CURRENT
0.0 A
Shows compressor current draw in amps.
Error messages
If the i-Series onboard diagnostics discover a problem,
the unit will display an error message. See "System
Status Messages" and "Error Messages," p. 8, for a
summary of messages.
4
OUTLET
00° 00%
to toggle between ON and OFF.
to select
to cycle through the
Dri-Eaz Products, Inc.
to