below). The second line of the display alternates be-
tween inlet temperature and inlet humidity.
User Settings Menu
A number of display settings may be changed by the
user. System information can also be displayed. These
items are accessed by pressing
Each press of the key will display the next parameter.
When you reach the parameter you wish to adjust, press
MENU SELECTION to increase the value. Press
DISPLAY MENU again to accept the setting and re-start
the display cycle. If no keys are selected for 5 minutes
the display will automatically reset and return to the
normal display mode.
CONTROL PANEL
ON/OFF
ON/OFF
DISPLAY MENU
MENU SELECTION /
UP KEY
PURGE PUMP
Note that only menu items followed by a greater-than
symbol ( > ) may be adjusted.
All settings and modes are discussed in detail in Control
Panel Guide, below.
Error messages
If the Revolution onboard diagnostics discover a prob-
lem, the unit will display an error message. See "System
Messages," p. 6 for an explanation of each message.

Control Panel Guide

ON/OFF. Press to turn the unit on or off. When the
machine is turned on, the display normally reads
PLEASE WAIT COMP. DELAY and performs a numeral
countdown for a maximum of 60 seconds to 0. This de-
lay allows time for refrigerant pressures to equalize for
easier starting. Once the unit completes the compressor
delay, the display shows UNIT ON XX HRS and cycles
07-01839B F413-115V 2013-12 Warranty 07-00420
DISPLAY MENU.
PURGE PUMP
SELECTION /
MENU
UP KEY
Press and release to turn unit on
or off.
Press to select next item in menu.
Menu item will show in display.
Press to toggle or select values in
menu displayed.
Press and release to start purge.
Display will count down seconds
remaining until purge is complete.
between INLET XX°F and INLET XX%. NOTE: If no
compressor delay countdown is displayed, a delay is not
necessary and the machine will begin operation immedi-
ately.
DISPLAY MENU. Press to cycle through the display
of additional dehumidifier conditions and User Settings.
To return to the main menu, press the ON/OFF key
once.
MENU SELECTION. Press to change the values of
the "User Defined" settings. The MENU SELECTION
key acts as the UP key for adjusting the setpoint for Hu-
midistat mode operation. See User Settings Menu (be-
low) for details.
PURGE. Press to empty water from the condensate
pump reservoir. The display will read PUMP PURGING
with a numeral countdown. NOTE: During normal opera-
tion, the pump purges automatically every 20 minutes, or
whenever the reservoir is full.
Changing settings and viewing system information
Display setting changes and system information can be
accessed by pressing
of the key will display the next parameter (see list be-
low). When you reach the parameter you wish to adjust,
press
MENU SELECTION to increase the value.
Press
DISPLAY MENU again to accept the setting
and re-start the display cycle. If no keys are selected for
5 minutes the display will automatically reset and return
to the normal display mode.
Note that only menu items followed by a greater-than
symbol ( > ) may be adjusted.
JOB HOURS
RESET? >
Press
MENU SELECTION to reset hours to zero.
NOTE: When in Humidistat mode, the unit will display
HUMIDISTAT on the top line during normal operation
rather than JOB HOURS.
LIFE HOURS
00 HRS
Shows total unit operating hours. Value cannot be modi-
fied.
INLET
00° 00%
Shows current temperature and RH of inlet and outlet.
3
DISPLAY MENU. Each press
OUTLET
00° 00%
Dri-Eaz Products, Inc.