Startup display and normal display modes
When unit is first plugged in to AC power, the control
panel display will briefly cycle through a series of
readouts. This is part of the unit's self-diagnosis
procedure and no user intervention is required.
Once the self-diagnosis is complete, the display will
switch to normal display mode.
UNIT ON 00 HRS
INLET 00°C / INLET 00%
The first line of the display shows the total number of
hours the unit has been in operation. This value may be
reset to zero to track job hours (see "Job Hours Reset"
below). The second line of the display alternates
between inlet temperature and inlet humidity.
User Settings Menu
A number of settings may be changed by the user.
System information can also be displayed. These items
are accessed by pressing DISPLAY MENU. Each press
of the key will display the next parameter. When you
reach the parameter you wish to adjust, press MENU
SELECTION to increase the value. Press DISPLAY
MENU again to accept the setting and re-start the
display cycle. If no keys are selected for 20 seconds the
display will automatically reset and return to the normal
display mode.
Note that only menu items followed by a greater-than
symbol ( > ) may be adjusted. All settings and modes are
discussed in detail in User Settings, below.
Error messages
If the Unit onboard diagnostics discover a problem, the
unit will display an error message. See "Error
Messages," below, for an explanation of each message.

Control Panel Guide

ON/OFF
ON/OFF
Press and release to turn unit on
or off.
DISPLAY MENU
Press to select next item in menu. Menu
item will show in display.
MENU SELECTION /
Press to toggle or select values in menu
UP KEY
displayed.
PURGE PUMP
Press and release to start purge. Display
will count down seconds remaining
until purge is complete.
07-01776N F412
PURGE
MENU
MENU
SELECTION /
UP KEY
ON/OFF. Press to turn the unit on or off. When the
machine is turned on, the display normally reads
PLEASE WAIT COMP. DELAY and performs a numeral
countdown from a maximum of 60 seconds to 0. This
delay allows time for refrigerant pressures to equalize for
easier starting. Once the unit completes the compressor
delay, the display shows UNIT ON XX HRS and cycles
between INLET XX°F and INLET XX%. NOTE: If no
compressor delay countdown is displayed, a delay is not
necessary and the machine will begin operation
immediately.
DISPLAY MENU. Press to cycle through the display of
additional dehumidifier conditions and User Settings. To
return to the main menu, press the ON/OFF key once.
MENU SELECTION. Press to change the values of the
"User Defined" settings. The MENU SELECTION key
acts as the UP key for adjusting the setpoint for
Humidistat mode operation. See User Settings Menu
(below) for details.
PURGE. Press to empty water from the condensate
pump reservoir. The display will read PUMP PURGING
with a numeral countdown.
NOTE: During normal operation, the pump purges auto-
matically.