SYSTEM MESSAGES

The Control Panel will display the following messages based on system performance and environmental conditions. User
action, if any is required, is indicated in the third column.
C O N T R O L P A N E L
M E S S A G E
INITIALIZING
FIRMWARE VERSION
XXX
FXXX-XXX
OFF
PLEASE WAIT
COMP. DELAY XX
UNIT ON XXXX HRS
INLET XXX°F / XX%
HUMIDISTAT
INLET XXX°F / XX%
LOW TEMP
INLET XXX°F/ XX%
---
PUMP PURGING XX
HI TEMP CYCLE
REMAINING XX MIN
---
DEFROST XX
WAIT FOR
DEFROST XXX
WAIT FOR
UNIT DRYING XXX
CHECK FILTER >
---
CLEAN COILS >
--

ERROR MESSAGES

If the control system detects an error, it will produce an error ("ER") message. If this occurs, first unplug the unit and then
plug it back in. This will usually reset the electronics, and the unit will begin operating normally. If the error message
reappears, refer to the explanations and solutions shown below. If these solutions do not fix the problem, contact your
local authorized service center.
07-01776N F412
E X P L A N A T I O N
Unit is powering up.
Indicates control board firmware version number.
Model number.
Unit has finished powering up and is operating.
60s delay before compressor turns on. Allows system
pressure to equalize.
First line: indicates total operating hours.
Second line: Toggles between inlet temperature and
inlet RH every 2 seconds.
First line: indicates unit is in humidistat mode
Second line: Toggles between inlet temperature and
inlet RH every 2 seconds.
Unit shuts off if inlet temp below 45°F/7°C. Turns back
on when inlet reaches 50°F/10°C.
Displays when the Pump Purge button is pressed.
Shows time remaining in seconds.
Unit overload limit reached. Cool-down initiated.
Unit is defrosting, with countdown in seconds.
Unit turned off when coil is cold or already in a defrost
cycle. Proceeds to finish cycle or initiate one to clear the
coils of ice before storage.
Occurs when unit is turned off and coil is not frozen.
Clears the coils of water before storage.
Prompt to change filter.
Prompt to clean coils and interior.
8
U S E R A C T I O N
None
None
None
None
None
None
None
None
None
None
None
None
None
Change filter. Press the > key
to reset
Clean coils. Press the > key
to reset