Inspect rotor belt. Check for proper tension. Belt should deflect no more than ¼ in. (0.6 cm) under moderate finger pres-
sure ~2lbs. of force. If belt deflects excessively or if it has cracks or excessive wear, contact your local distributor for in-
structions.
Vacuum interior to remove dust and debris. Wipe interior surfaces with clean, dry cloth. Do not apply water or cleaning
solutions of any kind. Take care not to damage electronic sensors and wires.
Reattach side panel. Reattach sensor cable inside panel. Thread the cable up through the zip tie and then plug in the
cable. Now install screws, finger tight only, starting at the top and working down. Once all screws are properly started,
then use a hand tool to tighten the screws snugly. Do not overtighten. Do not use a power tool to tighten screws.

SYSTEM MESSAGES

If the control system detects an error, it will produce an error ("ER") message. If this occurs, first unplug the unit and then
plug it back in. This will usually reset the electronics, and the unit will begin operating normally. If the error message reap-
pears, refer to the explanations and solutions shown below. If these solutions do not fix the problem, contact your local
authorized service center.
NOTE: The message "POWER FAILURE" is not a system error. When this message is displayed, it indicates that
power to unit was interrupted and then restored. To clear the message, press the
C O N T R O L P A N E L
M E S S A G E
ER1 CONTACT SERVICE
CENTER
ER2 CONTACT SERVICE
CENTER
ER3 CHECK
ROTOR MOTOR
ER4 CHECK
AIRFLOW
ER5 REACT
SENSOR CONNECT
or
ER5 PROCESS
SENSOR CONNECT
ER6 SENSOR
CONNECTION ON BD
ER7 CONTACT
SERVICE CENTER
ER8 INVALID
MODEL SETTING
E X P L A N A T I O N A N D S O L U T I O N
Indicates a serious internal problem. The electronic control panel may require replace-
ment. Contact service.
Air Inlet temperature set point for cycling air conditioner to control temperature.
Check AC power for low voltage.
Control panel error. The electronic control panel may require replacement. If error per-
sists, contact service.
React Temp minus Inlet Temp difference too high indicates rotor stopping – belt or drive
motor issue. Check belt tension, belt failure, rotor cleats, and motor operation.
Heater amps too low indicates fan issue and/or inlet airflow restriction. Clear any ob-
structions from inlet and/or check fan operation.
Temp sensor is open, missing, or shorted. Check that temp sensors are installed cor-
rectly on control panel. If error persists, contact service.
Inlet Temp/RH sensor is open, missing, or shorted. Check that inlet temp/RH sensor is
installed correctly on control panel and inlet shroud. If error persists, contact service.
Current sensor failure. If error persists, contact service.
Incorrect or unsupported DIP switch settings. Contact Dri-Eaz service department for
correct DIP switch settings.