System Status And Data Messages; Error Messages - Dri-Eaz LGR 2800i Guide D'utilisation

Masquer les pouces Voir aussi pour LGR 2800i:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SYSTEM STATUS AND DATA MESSAGES

The table below is a summary of status and data messages produced by the i-Series dehumidifers. The left column shows
the messages that appear on the control panel display. The center column shows the messages that are relayed to the
HygroTrac remote monitoring system and displayed on the HygroTrac website. The HygroTrac website will also display
one of three status messages for each i-Series unit detected by a HygroTrac gateway: S for standby (the unit is
disconnected from AC power but the wireless transmitter is working properly), A for active (the unit is sending normal data
and status messages), or I for inactive (the unit is sending no messages).
C O N T R O L P A N E L
M E S S A G E
UNIT ON 00 HRS
UNIT ON 00 HRS
DEFROST CYCLE
OFF
UNIT ON 00 HRS
POWER FAILURE>
HUMIDISTAT
INLET XXX°F
HI TEMP CYCLE
REMAINING 00 MIN
[display is blank]

ERROR MESSAGES

The table below shows error messages that the system may display. If the display shows an "ER" message, first unplug
the unit and then plug it back in. This may re-set the electronics, and if so, no further action is required. If the error
message reappears, try the solution shown under "Explanation." If this still does not fix the problem, contact your local
authorized service center or the Dri-Eaz Service Department at 800-932-3030.
C O N T R O L P A N E L
M E S S A G E
ER1 CONTACT SERVICE
CENTER
ER2 CONTACT SERVICE
CENTER
ER3 CONTACT SERVICE
CENTER
07-01674F 2011-04 Warranty 07-00420
H Y G R O T R A C
W E B S I T E M E S S A G E
Dehumidifier On
In Defrost Mode
Dehumidifier Off AC power
present.
Dehumidifier Restarted after
Power Failure
Humidistat Controlled
In High Temp mode
Stand-by Mode
H Y G R O T R A C
W E B S I T E M E S S A G E
Failure: Contact Service
Center
Failure: Contact Service
Center
Failure: Contact Service
Center
9
E X P L A N A T I O N
Normal operation.
Normal operation. Unit is in defrost mode. No
action required.
Unit is turned off. AC power present.
Unit experienced a power failure but has
successfully restarted. Press > to clear this
message.
Humidistat mode is active and dehumidifier
energized.
LGR 2800i only. Indicates normal operation. Unit
has detected higher ambient temperatures and
switched modes to operate more efficiently. No
action required.
No AC power. Wireless transmitter functioning
normally. No action required.
E X P L A N A T I O N
Check AC power for inadequate voltage. The
electronic control panel may require replacement.
Contact service.
The electronic control panel may require
replacement. Contact service.
Check defrost sensor for proper connection.
Check sensor cable for damage. Sensor assem-
bly may need replacement. Contact service.
Dri-Eaz Products, Inc.

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Lgr 3500iF410F411Lgr i serie

Table des Matières