Transportation And Storage - Dri-Eaz LGR 2800i Guide D'utilisation

Masquer les pouces Voir aussi pour LGR 2800i:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

pump and tray assembly out of the unit.
12. Lift pump body out of plastic catch tray.
13. Wipe or rinse off all surfaces of the plastic catch tray
with a damp cloth.
CLEANING THE PUMP AND PUMP TRAY
14. Remove the pump assembly from the pump tray and
set pump aside. Wipe or rinse out pump tray and wipe
dry.
15. Remove pumpout hose from the check valve outlet.
16. Unscrew check valve. Using needle nose pliers
carefully remove bottom of check valve assembly by
inserting one side of pliers approximately ⅛ in. into hole,
grasp and pull out carefully. A small ball bearing should
fall out so be careful not to lose it. Inspect assembly for
debris in assembly and clean accordingly. Reinstall the
ball bearing and reinstall the check valve assembly.
Reassemble in reverse order. The dehumidifier is now
ready for use.
07-01674F 2011-04 Warranty 07-00420
Annually
Have the pump system inspected by the Dri-Eaz Service
Department (800-932-3030) or by a qualified service
center.

TRANSPORTATION AND STORAGE

NOTICE: Handle the unit carefully. Do not drop, throw,
or place the unit where it could fall. Rough treatment
can damage this equipment and may create a
hazardous condition or void warranty.
IMPORTANT: Be sure to purge the water from the
pump reservoir before moving the unit. See the
PURGE function under "How to use the control panel"
on p. 4. Note that the unit must be plugged in for the
Purge function to operate.
1. Do not expose the control panel to moisture, snow or
rain when transporting in uncovered vehicles such as
flatbed trucks.
2. Store and transport securely to avoid any damaging
impact to internal parts.
7
Dri-Eaz Products, Inc.

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Lgr 3500iF410F411Lgr i serie

Table des Matières