Reassemble in reverse order. The dehumidifier is now
ready for use.
Annually
Have the pump system inspected by the Dri-Eaz Service
Department (800-932-3030) or by a qualified service
center.

TRANSPORTATION AND STORAGE

IMPORTANT: Before moving, transporting or
storing, purge unit and stow hose and power cord as
described in the "At the End of the Job" section
above.
NOTICE: Handle the unit carefully. Do not drop, throw or
place the unit where it could fall. Rough treatment can
damage the dehumidifier and may create a hazardous
condition or void the warranty.
• Do not expose the control panel to moisture, snow
or rain.
• Store and transport securely to avoid any damaging
impact to internal parts.
• Secure during transport to prevent sliding and
possible injury to vehicle occupants.
• Do not transport or store the unit on its front, sides or
back. This will help to prevent any remaining moisture
from escaping from the unit or flowing into areas
outside the sump.
CLEANING COILS AND HEAT
EXCHANGE BLOCK
Warning! Unplug unit before servicing.
To help keep the unit operating efficiently, keep the coils
and the air-to-air heat exchange block clean. Access
these components by removing the side and rear covers:
07-01674N F410, F411
1. Unplug unit.
2. Unplug the power cord from the socket at the base of
the unit. Remove pump hose at quick-connect.
3. Remove filter.
4. Remove both side covers A and B (unscrew two bolts
shown for each panel).
5. Remove back cover (unscrew the four bolts shown on
the back and the two bolts on the upper front panel).
6. Remove the heat exchange block.
Inspect the heat exchange block carefully. If necessary,
use compressed air to clear the channels of the block,
taking care not to damage the block.
NOTICE: The unit is fitted with sensitive electronic
sensors. Protect the sensors from impact and do not
expose them to water or cleaning solution.
Vacuum or use compressed air on both sides of the
upright (condenser) coil until it is clean. Take care not to
let the nozzle touch the fins; as this may damage the
fins. A coil cleaner product may be used on the
horizontal cold (evaporator) coil only. Follow instructions
on product label. Take care not to spray or wipe product
on or near any electrical components or sensors. To
clean the vertical (condenser) coil, contact Service for
instructions.
To reassemble, follow the above steps in reverse. Be
sure to reinstall heat exchange block in the original
orientation. When installing the rear cover, carefully
thread the pump hose through the hole in the back
pocket before putting the cover in place.
NOTICE: Rubber strips are attached to the outside
edges of the evaporator and condenser coils to
provide an airtight seal around the heat exchange
block. When reinstalling the block, make sure the
seals are in place and are not kinked or folded.
8