At The End Of The Job; Transportation And Storage - Dri-Eaz LGR 7000XLi Guide D'utilisation

Masquer les pouces Voir aussi pour LGR 7000XLi:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

accessed by pressing
of the key will display the next parameter (see list
below). When you reach the parameter you wish to
adjust, press
MENU SELECTION to increase the
value. Press
DISPLAY MENU again to accept the
setting and re-start the display cycle. If no keys are
selected for 20 seconds the display will automatically
reset and return to the normal display mode.
Note that only menu items followed by a greater-than
symbol ( > ) may be adjusted.
JOB HOURS
RESET? >
Press
MENU SELECTION to reset hours to zero.
NOTE: When in Humidistat mode, the unit will display
HUMIDISTAT on the top line during normal operation
rather than JOB HOURS.
LIFE HOURS
00 HRS
Shows total unit operating hours. Value cannot be
modified.
INLET
OUTLET
00° 00%
00° 00%
Shows current temperature and RH of inlet and outlet.
Humidistat Mode
HUMIDISTAT MODE
ON/OFF >
In ON mode, unit will maintain the humidistat setpoint
(see below). Press
MENU SELECTION to toggle
between ON and OFF. NOTE: When in Humidistat
mode, the unit will display HUMIDISTAT on the top line
during normal operation rather than JOB HOURS.
HUMIDISTAT
SETPOINT 00% >
Sets humidity level when unit is in Humidistat Mode.
Press
MENU SELECTION to change RH value. Each
press of the button increases the setting by 5%
increments, cycling through 90%RH and starting again
at 30%RH.
TEMP UNITS
F° >
Shows current temperature scale. Press
SELECTION to select Fahrenheit or Centigrade scale.
LANGUAGE
ENGLISH >
Shows current display panel language. Press
SELECTION to select Spanish, German, French or
English.
07-01776D (F412 120V) 2013-01 Warranty 07-00420
DISPLAY MENU. Each press
MENU
MENU
COIL TEMP
00°F
Displays the cold (evaporator) coil temperature.
SENSOR ID >
00000000
This function is not used on the 7000XLi.
COMPRSSR CURRENT
0.0 A
Shows compressor current draw in amps.

AT THE END OF THE JOB

To reduce the possibility of drips when moving the unit,
follow these additional steps to ensure that all water is
removed from the unit.
NOTICE: To ensure the condensate tank empties
completely while purging, make sure the unit is set fully
upright.
1. If the unit is in a defrost cycle, wait until the unit has
returned to normal operating mode before proceeding.
To check, review the control panel. The control panel will
show one of the following:
Defrost in progress:
UNIT ON 00 HRS
DEFROST CYCLE
Normal Display:
UNIT ON 00 HRS
INLET XX° F
Wait until the control shows the normal display before
proceeding.
2. Gently rock the upright machine on its wheels to
ensure any water remaining on interior surfaces falls into
the sump area.
3. Press the
PURGE key. When the purge cycle is
complete, turn the unit off.
4. Remove the external drain hose, drain it carefully, and
return it to the pocket provided on the side of the unit.
5. Unplug power cord from power supply and from base
of the machine, coil neatly, and return it to the coil
storage pocket (see Fig. A).

TRANSPORTATION AND STORAGE

NOTICE: Handle the unit carefully. Do not drop, throw,
or place the unit where it could fall. Rough treatment can
damage this equipment and may create a hazardous
condition or void warranty.
• Do not expose the control panel to moisture, snow
or rain.
4