Transportation And Storage; Cleaning And Maintenance - Dri-Eaz LGR 7000XLi Guide D'utilisation

Déshumidificateur portable
Masquer les pouces Voir aussi pour LGR 7000XLi:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

HUMIDISTAT
SETPOINT 00% >
Sets humidity level when unit is in Humidistat Mode (see
above). Press
MENU SELECTON to change RH
value. Each press of the button increases the setting by
5% increments, cycling through 90%RH and starting
again at 30%RH.
TEMP UNITS
F° >
Shows current temperature scale. Press
SELECTON to select Fahrenheit or Centigrade scale.
LANGUAGE
ENGLISH >
Shows current display panel language. Press
SELECTON to select Spanish, German, French or
English.
COIL TEMP
00°F
Displays the cold (evaporator) coil temperature.
SENSOR ID >
00000000
This function is not used on the 7000XLi.
COMPRSSR CURRENT
0.0 A
Shows compressor current draw in amps.
Error messages
If the 7000XLi onboard diagnostics discover a problem,
the unit will display an error message. See "Error
Messages," p. 7, for an explanation of each message.
At the end of the job
Before removing the unit from the job site, make sure the
unit is completely purged of water before moving it:
1. Press the
PURGE key. When the purge cycle is
complete, turn the unit off.
2. Remove the external drain hose, drain it carefully, and
return it to the pocket provided on the side of the unit.
Special Tip:
Before transporting unit on stairs, follow these additional
steps to ensure that all water is removed from the unit:
1. Turn the unit off after a defrost cycle has been
completed. Gently rock the upright machine on its
wheels to ensure any water remaining on interior
surfaces falls into the sump area.
2. Press the
PURGE key. When the purge cycle is
complete, turn the unit off.
3. Remove the external drain hose, drain it carefully, and
return it to the pocket provided on the side of the unit.
NOTICE: To ensure the condensate tank empties
completely while purging, make sure the unit is set fully
upright.

TRANSPORTATION AND STORAGE

NOTICE: Handle the unit carefully. Do not drop, throw,
or place the unit where it could fall. Rough treatment can
damage this equipment and may create a hazardous
condition or void warranty.
• Do not expose the control panel to moisture, snow
MENU
• Store and transport securely to avoid any damaging

CLEANING AND MAINTENANCE

MENU
WARNING! ELECTRIC SHOCK HAZARD. Unplug the
dehumidifier before performing any maintenance.
Before each use
Inspect the electrical cord for damage. Look for
fraying, cuts, etc. Do not use the unit if you find any
damage.
Inspect, vacuum or replace filter. The High Airflow
(HAF) filter may be vacuumed clean and reused up to
three times before replacement. Replace only with a new
HAF filter (Dri-Eaz part no. F368). See "About HAF
Filters," below.
Monthly
Check coils. Dirty or dusty coils can cause the unit to
overheat. Clean when dust accumulation is visible. See
"Cleaning Coils and Heat Exchange Block," below.
Check heat exchange block. Clean out with
compressed air only. Take care not to damage the block.
See instructions below.
Inspect and clean the pump. See instructions, right.
CLEANING COILS AND HEAT
EXCHANGE BLOCK
WARNING: Unplug unit before servicing.
To help keep the unit operating efficiently, keep the coils
and the air-to-air heat exchange block clean. These
components are easily accessed by removing the cover
and rear panel as described below:
NOTICE: The unit is fitted with sensitive electronic
sensors. Protect the sensors and their lead wires from
damage and do not expose them to water or cleaning
solution.
NOTICE: Before removing the heat exchange block for
cleaning or service, disconnect the sensor chip
assembly (Fig. D) from the block. Gently pull up on the
or rain.
impact to internal parts.

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

F412

Table des Matières