Plug in electrical cord
The 7000XLi dehumidifier should be plugged into a
GFCI-protected 115 volt outlet rated for at least 15 amps.
Remove the cord from its storage pocket and uncoil it.
Always plug the cord firmly into the unit first, and then
plug the other end into a suitable outlet.
Turn the unit on
The control panel on the 7000XLi dehumidifier has a
display and a touchpad with four keys. Press the
ON/OFF to turn the unit on.
How to use the control panel
The control panel on the 7000XLi has a display and a
touchpad with four keys.
ON/OFF. Press to turn the unit on or off. When the
machine is turned on, the display normally reads
PLEASE WAIT COMP. DELAY and performs a numeral
countdown from a maximum of 60 seconds to 0. This
delay allows time for refrigerant pressures to equalize for
easier starting. Once the unit completes the compressor
delay, the display shows UNIT ON XX HRS and cycles
between INLET XX°F and INLET XX%. NOTE: If no
compressor delay countdown is displayed, a delay is not
necessary and the machine will begin operation
immediately.
DISPLAY MENU. Press to cycle through the display
of additional dehumidifier conditions and User Settings.
To return to the main menu, press the ON/OFF key
once.
MENU SELECTION. Press to change the values of
the "User Defined" settings. The MENU SELECTON key
acts as the UP key for adjusting the setpoint for
Humidistat mode operation. See User Settings Menu
(below) for details.

CONTROL PANEL

DISPLAY
ON/OFF
DISPLAY
MENU
PURGE. Press to empty water from the condensate
pump reservoir. The display will read PUMP PURGING
with a numeral countdown. NOTE: During normal
PURGE PUMP
MENU
SELECTION /
UP KEY
operation, the pump purges automatically every six
minutes, or whenever the reservoir is full.
Main menu display
When unit is first plugged in to AC power, the control
panel display will briefly cycle through a series of
displays. This is part of the unit's self-diagnosis
procedure and no user intervention is required.
Once the self-diagnosis is complete, the display will
show the following information:
UNIT ON 00 HRS
INLET 00°F / INLET 00%
The first line of the display shows the total number of
hours the unit has been in operation. This value may be
reset to zero to track job hours (see "Job Hours Reset"
below). The second line of the display alternates
between inlet temperature and inlet humidity.
User settings menu
A number of settings may be changed by the user.
System information is also available. These items are
accessed by pressing
the key will display the next parameter (see list below).
When you reach the parameter you wish to adjust, press
MENU SELECTON to increase the value. Press
DISPLAY MENU again to accept the setting and re-start
the display cycle. If no keys are selected for 20 seconds
the display will automatically reset and return to the
normal display mode.
Note that only menu items followed by a greater-than
symbol ( > ) may be adjusted.
JOB HOURS
RESET? >
Press
MENU SELECTON to reset hours to zero.
NOTE: When in Humidistat mode, the unit will display
HUMIDISTAT on the top line during normal operation
rather than JOB HOURS.
LIFE HOURS
00 HRS
Shows total unit operating hours. Value cannot be
modified.
INLET
00° 00%
Shows current temperature and RH of inlet and outlet.
HUMIDISTAT MODE
ON/OFF >
In ON mode, unit will maintain the humidistat setpoint
(see below). Press
MENU SELECTON to toggle
between ON and OFF. NOTE: When in Humidistat
mode, the unit will display HUMIDISTAT on the top line
during normal operation rather than JOB HOURS.
DISPLAY MENU. Each press of
OUTLET
00° 00%