outlets, have proper outlets installed by a qualified
electrician.
This equipment is for use on circuits with a nominal rat-
ing of no more than 120V.
Handle the unit carefully
Always operate the unit on a stable, level surface. Do
not drop, throw, or place where it could fall. Rough treat-
ment can damage the unit, and may create a hazardous
condition or void the warranty.
This unit intended for household and commercial use.

BEFORE FIRST USE

The unit is shipped with two duct rings and an adaptor kit
packed inside the storage compartment. A 3 mm Allen
wrench is required for installation of these components.
Required: Install Reactivation Air Outlet duct ring
Install the Reactivation Duct Ring, See Fig. B.
Optional: Install Air Inlet duct ring
Attach to inlet with the thumbscrews provided. See Fig.
B.
Optional: Install Process Air Outlet offset screws
The Process Air Outlet Adaptor Kit may be installed us-
ing the offset screws provided. See Fig. B.
CONTROLS AND OPERATING
INSTRUCTIONS
Positioning the Dehumidifier

CONTROL PANEL

ON/OFF
DISPLAY MENU
MENU SELECTION /
UP KEY
WATER REMOVAL
For best results, operate your dehumidifier in an en-
closed area. Close all doors and windows that open to
49-109H F533
Press the
When the machine is turned on, the display normally reads PLEASE WAIT
WARMING UP. Once the unit completes the warm-up procedure, the display
shows UNIT ON XXX HRS and cycles between INLET XXX°F and INLET XX%
(RH).
Cycles through the display of additional dehumidifier conditions and User Set-
tings. To return to the main menu, press the ON/OFF key once.
Change system settings. The MENU SELECTION key acts as the "UP" key for
cycling through the setpoints.
Press and release to show a calculated amount of water removal in pints/day.
The unit will display WATER REMOVAL XXX PINTS/24H after 5 minutes of
run time. The display will automatically return to the "Unit On" display after a
few seconds.
2
Fig. A: Parts Identification
Air filter
Air inlet
Reactivation
Air Outlet
(installation
of duct re-
quired)
the outside to maximize water removal efficiency. Place
your dehumidifier away from any obstructions that could
block airflow into and out of the unit. Duct reactivation
outlet outdoors through window adapter or dryer vent.
Plug in electrical cords
Always plug the cords firmly into the sockets in the
top compartment first, then into the wall outlets. En-
sure that the cords are routed properly through the
cord cutout notch before closing the storage com-
partment lid.
NOTICE: The power cords of the DriTec must be
plugged into separate GFCI-protected 120V outlets rated
for at least 15A.
ON/OFF to turn the unit on.
Power sockets inside
compartment. Stor-
age for power cords,
react ducting.
Control panel
Process Air Out-
let (optional duct
attachment kit
provided)
Dri-Eaz Products, Inc.