Maintenance Schedule; Before Each Use - Dri-Eaz LGR 6000Li Manuel D'utilisation

Masquer les pouces Voir aussi pour LGR 6000Li:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

• Store and transport securely to avoid any
damaging impact to internal parts.
• Secure during transport to prevent sliding and
possible injury to vehicle occupants.
• Do not transport or store the unit on its front, sides
or back. This will help to prevent any remaining
moisture from escaping from the unit or flowing into
areas outside the sump.

MAINTENANCE SCHEDULE

WARNING! ELECTRIC SHOCK HAZARD. Unplug the
dehumidifier before performing any maintenance.
WARNING: Risk of dust and contaminants exposure.
Use of respirator mask and gloves is recommended. If
unit has been exposed to potentially dangerous
contaminants, clean thoroughly and sanitize before
reuse.
NOTICE: The unit is fitted with sensitive electronic
sensors. Protect the sensors and their lead wires from
damage and do not expose them to water or cleaning
solution.
The following tools and supplies are needed to
complete the maintenance procedures described in
this manual:
Philips screwdriver
T-20 Torx bit
10 mm nutdriver or socket and ratchet
Cleaning cloths
HEPA vacuum cleaner with soft brush nozzle and
crevice tool.
Recommended
Cordless drill, small knife, small-jaw pliers, coil
cleaning solution, rotomolded housing cleaning
solution.

Before each use

Inspect the electrical cord for damage. Look for
fraying, cuts, etc. Replace the cord if you find any
damage.
Inspect filter. Replace if accumulation of dust and
debris is visible.
NOTICE: Replace used filters only with a new Dri-Eaz
filter part no. #100254 (F579) (24-pack). Other filter
108259F #103614 (F600)
Fig. B: Disassembly for Cleaning
Remove the 4
screws from front
housing and slide
off to access coils
and pump for
service.
types do not provide adequate filtration or airflow. Each
filter is individually wrapped to protect filtration
effectiveness. Remove the wrapper before installing the
filter into the dehumidifier.
Monthly
Inspect coils. Clean when dust accumulation is visible.
In normal use, dust can accumulate and can restrict
airflow, reducing performance and causing the unit to
overheat.
To maintain appearance, wipe interior and exterior
surfaces with a damp cloth. For deep cleaning and a
lasting, protective shine, use an automotive interior
treatment product.
As Needed
Clean Pump Check Valve and Basin. This requires
removal of the front housing.
Clean coils. Inspect the horizontal evaporator (cold) coil
with the front cover removed. If excessive dust and
debris is present, vacuum thoroughly and/or clean with
alkaline (non-acidic) coil cleaner.
5
Legend Brands, Inc.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

103614F600

Table des Matières