Dri-Eaz LGR 6000Li Manuel D'utilisation page 6

Masquer les pouces Voir aussi pour LGR 6000Li:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TROUBLESHOOTING
F A U L T
Water drips out
when moving unit
Unit does not
operate
Unit operating,
but room not dry
Unit collects too
little water
If the problem you are experiencing is not listed here, call your local distributor or contact
our Service Department at 800-932-3030 for further assistance.
SPECIFICATIONS
Model
Water removal AHAM
(80°F/60% RH)
Water removal saturation
(90°F/90% RH)
Process air (max.)
Dimensions
(H × D × W)
Weight
Amps
Volts
Frequency
Power
Operating range
Noise level (avg.)
Drain hose
Power cord
Construction
Safety
Specifications are subject to change without notice. Some values
may be approximate.
*Fan speed varies automatically for optimized performance.
108259F #103614 (F600)
C A U S E
Unit was unplugged before
purging was complete.
Unit not switched on.
No power to machine.
Not enough time to dry.
Poor air movement in room.
Excessive moist air infiltration.
Room air is dry.
Room temperature is too low.
Filter is full.
Coils are clogged.
LGR 6000Li (#103614 (F600))
100 pts. | 47.3 L / day
204 pts. | 96.5 L / day
320 CFM
32.1 × 19.8 × 20.0 in.
81.5 × 50.3 × 50.8 cm
103 lbs. | 46.7 kg
6.6A
115V
60Hz
759W
33°F–100°F | 1°C–38°C
53 dB
40 ft. | 12.2 m
25 ft. | 7.6 m
Rotomolded shell
ETL certified CSA 22.2 no. 92
S O L U T I O N
Purge unit before moving. See "At the End of the Job."
Switch unit on.
Plug in unit; check power cord connection at wall outlet and at
base of unit.
Make sure "Humidistat" is OFF.
Allow more time for drying.
Increase air movement with air movers.
Seal off area to reduce infiltration.
Make sure "Humidistat" is OFF.
Confirm humidity level with hygrometer.
Increase room temperature.
Check filter. Replace as necessary.
Check coils. Clean as necessary.
Order replacement air filters from your local distributor.
Part no. #100254 (F579) (24 pack).
Be sure to visit
Warranty.LegendBrandsRestoration.com
and register your purchase. Your registration will help us
provide you with updated product information as needed.
For proper disposal, this unit should be taken to a
recycler licensed to process refrigeration equipment.
WARNING: This product and other substances
that may become airborne from its use contain
chemicals, including lead and phthalates, known to the
State of California to cause cancer, birth defects, or
other reproductive harm. For more information, go to
P65Warnings.ca.gov