Maintenance - Dri-Eaz LGR 2800i Manuel D'utilisation

Masquer les pouces Voir aussi pour LGR 2800i:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

JOB HOURS
RESET? >
Press
to reset hours to zero. NOTE: When in
Humidistat m
ode, the unit wil
the top line du
ring normal o
HOURS.
LIFE HOURS
00 HRS
Shows total unit operating hours. Value cannot be
modified.
INLET
OUTLET
00° 00%
00° 00%
Shows current temperature and RH of inlet
The HygroTrac system uses these values t
grain depression.
HUMIDISTAT MODE
ON/OFF >
In ON mode, unit will maintain the humidistat setpoint
(see below). Press
to toggle b
NOTE: When i
n Humidista
HUMIDISTAT on the top line during normal operation
rather than JOB HO RS.
U
HUMIDISTAT
SETPOINT 00% >
Sets humidity level when unit is in Humidistat Mode (see
above). Press
to change RH valu
Settings cy
cle upward through
30%RH.
TEMPERATURE UNIT
F° >
Shows current temperature scale. Press
Fahrenh eit or Centigrade scale.
LANGUAGE
ENGLISH >
Shows current display panel language. Press
select Spanis
h, German, Fre
COIL TEMP
00°F
Displays the
cold (evaporator) coil temperature.
07-01674C 2009-08
l display HUMIDISTAT on
peration rather than JOB
and outlet.
o calculate
etween ON and OFF.
t mode, the unit will display
e at 5% increments.
90%RH and start again at
to select
to
nch or English.
SENSOR ID >
00000000
Shows built-in wireless transmitter number. The
HygroTrac system uses this to uniquely identify your
2800i unit. NOTE: For convenience, this same number is
shown on the barcode label affixed to the control panel.
Press
to cycle through the following values: SENSOR
TYPE, SENSOR REVISION, and SENSOR CONF REV.
A Dri-Eaz service technician may ask you for these
values when diagnosing a problem.
COMPRSSR CURRENT
0.0 A
Shows compressor current draw in amps.
Error messages
If the LGR 2800i onboard diagnostics discover a
problem, the unit will display an error message. If the
unit is used with the HygroTrac system, it will also
transmit most error messages to the user's HygroTrac
website. See "System Status and Data Messages" and
"Error Messages," p. 8, for a summary of messages.
At the end of the job
As with all dehumidifiers, once the drying job is
completed, it is important to make sure the unit is
completely purged of water before moving it. To ensure
that all water has drained into the pump, turn the
unit off, allow it to rest for 10 minutes, then press the
PURGE button. (The unit must be plugged in for the
purge to operate.) Once the purge cycle is complete,
unplug the unit and remove it promptly from the job.
Before transporting, be sure to remove the external drain
hose, drain it carefully, and return it to the pocket
provided on the front of the unit.

MAINTENANCE

WARNING! ELECTRIC SHOCK HAZARD. Unplug
the LGR 2800i dehumidifier before performing any
maintenance.
Before each use
Inspect the electrical cord for damage. Look for
fraying, cuts, etc. Do not use the unit if you find any
damage. Call Dri-Eaz for the nearest Service Center at
800-932-3030.
Inspect and vacuum filter as needed. The LGR 2800i
is equipped with a 3M™ High Air-Flow filter. The HAF
filter may be vacuumed clean and reused up to three
times. Do not rinse or wash the HAF filter, as it will
reduce the effectiveness of the electrostatic material.
Keep a clean filter in the unit at all times to protect
internal components from dust and other particulate
build-up. Vacuum or replace filter before each job.
Replace only with a new 3M HAF Filter (Dri-Eaz part no.