At the end of the job
As with all dehumidifiers, once the drying job is
completed, it is important to make sure the unit is
completely purged of water before moving it. To ensure
that all water has drained into the pump, follow
these steps:
1. Turn the unit off and allow the plugged in dehumidifier
to rest for 10 minutes.
2. Press the PURGE key and while the purge pump is
operating, tip the unit back approximately 45° and hold
the unit in place. The manual purge cycle lasts
approximately 10 seconds.
3. Return the unit to the upright position and press
PURGE one more time to empty the pump.
Remove the dehumidifier promptly from the job site
once these steps have been completed.
Before transporting, be sure to remove the external drain
hose, drain it carefully, and return it to the pocket
provided on the back of the unit.

MAINTENANCE

WARNING! ELECTRIC SHOCK HAZARD. Unplug the
dehumidifier before performing any maintenance.
Before each use
Inspect the electrical cord for damage. Look for
fraying, cuts, etc. Do not use the unit if you find any
damage. Call Dri-Eaz for the nearest Service Center at
800-932-3030.
Inspect and vacuum filter as needed. The i-Series
dehumidifiers are equipped with a 3M™ High Air-Flow
filter. The HAF filter may be vacuumed clean and reused
up to three times. Do not rinse or wash the HAF filter,
as it will reduce the effectiveness of the electrostatic
material.
Keep a clean filter in the unit at all times to protect
internal components from dust and other particulate
build-up. Vacuum or replace filter before each job.
Replace only with a new 3M HAF Filter (Dri-Eaz part no.
F421). For parts and service call your local distributor or
contact the Dri-Eaz Service Department at
800-932-3030 or 360-757-7776.
CAUTION: Dust can cause the unit to overheat and
shut down. Do not operate when excessive dust or
airborne particles are present, such as during
sanding or spray-painting. Inspect and clean air filter
elements and coils frequently.
IMPORTANT: Replace the HAF filter whenever 1)
it has been vacuumed clean 3 times or 2) it has
been used on a mold remediation job or
otherwise exposed to potentially dangerous
contaminants.
07-01674J F410, F411
Monthly
Check coils. Dirty coils can cause the unit to overheat.
Clean when visibly dirty. See "Instructions for Cleaning,"
p. 7.
Check heat exchange block. Clean out with
compressed air only. Take care not to damage the block.
Inspect and clean the pump. To remove the
condensate pump unit:
SERVICING THE PUMP AND DRAIN PAN
To maintain proper operation, the pump and drain pan
assembly should be periodically removed and cleaned.
Follow these steps to clean the pump and drain pan
assembly:
Tools Needed
Philips screwdriver
Flat blade screwdriver
⅜ in. and
15
in. sockets and driver
16
Cleaning cloths
DISASSEMBLY AND CLEANING
1. Unplug unit, then remove the power cord from the
socket at the base of the unit. Remove pump hose at
quick-connect.
2. Remove HAF filter.
3. Remove the two bolts from the upper front cover.
4. Remove one bolt each from the upper back corner of
side covers A and B (see Fig. A)
5. Remove four bolts from the lower back panel. The
back/top panel may now be removed.
6. Remove lower back metal panel (unscrew the five
attachment screws).
7. Place a firm support under the base of the unit so that
the left wheel may be removed.
8. Using the flat blade screwdriver, carefully pry the
center hub cap loose from the left wheel. Use the
socket to remove the retaining nut and slide the wheel
off. See Fig E, #1.
9. Remove the two electric box retaining screws (see Fig
E, #2.).
10. Tilt the bottom of the electric box to the right and
slide outward (Fig F). It is not necessary to disconnect
any electrical cables.
11. Remove drain hose from pump assembly and slide
pump and tray assembly out of the unit.
12. Lift pump body out of plastic catch tray.
13. Wipe or rinse off all surfaces of the plastic catch tray
with a damp cloth.
CLEANING THE PUMP AND PUMP TRAY
14. Remove the pump assembly from the pump tray and
set pump aside. Wipe or rinse out pump tray and wipe
dry.
15. Remove pumpout hose from the check valve outlet.
16. Unscrew check valve. Using needle nose pliers
carefully remove bottom of check valve assembly by
inserting one side of pliers approximately ⅛ in. into hole,