BEFORE FIRST USE

The unit is shipped with two duct rings and an adaptor kit
packed inside the storage compartment. A 3 mm Allen
wrench is required for installation of these components.
Required: Install Reactivation Air Outlet duct ring
Install the Reactivation Duct Ring, 20 ft. of 6 in. ducting
using duct clamp provided and duct to the outdoors. See
Fig. B.
Optional: Install Air Inlet duct ring
The Air Inlet Duct Ring may be installed using the four
screws provided. See Fig. B.
Optional: Install Process Air Outlet offset screws
The Process Air Outlet Adaptor Kit may be installed us-
ing the offset screws provided. See Fig. B.
CONTROLS AND OPERATING
INSTRUCTIONS
Positioning the Dehumidifier
For best results, operate your dehumidifier in an en-
closed area. Close all doors and windows that open to
the outside to maximize water removal efficiency. Place
your dehumidifier away from any obstructions that could
block airflow into and out of the unit. Duct reactivation
outlet outdoors through window adapter or dryer vent.
Plug in electrical cords
NOTICE: The power cords of the DriTec must be
plugged into separate GFCI-protected 120V outlets rated
for at least 15A. Always plug the cords firmly into the
sockets in the top compartment first.
Fig. B: Initial Setup
1. Install Reactivation Out Duct Ring (required)
2. Install Air in Duct Ring (optional)
1. React outlet duct
ring. MUST BE
INSTALLED
A: Parts Identification
Air filter
Air inlet
Reactivation
Air Outlet
(installation
of duct re-
quired)
NOTICE: Connect to two separate 15A circuits ONLY. A
bright green light indicates correct connections. No light
will show when using only one cord or if both power
cords are plugged into the same power circuit.
Startup display and normal display modes
When unit is first plugged in to AC power, the control
panel display will briefly cycle through a series of
readouts. This is part of the unit's self-diagnosis proce-
dure and no user intervention is required.
Ducting Setup
NOTICE! For indoor use only. Do not expose the unit
to rain or snow. If electrical components become
wet, allow the unit to dry thoroughly before operat-
ing.
3. Install Process Air Outlet Duct (optional)
Process air
outlet grille
Square wire
ducting frame
2. Process air in
duct (optional)
1. Install 4 standoff
screws as shown.
3. Place wire frame inside offset screws and
click into place. When not in use, frame may be
left in standoffs or placed in storage bin.
Power sockets inside
compartment. Stor-
age for power cords,
react ducting.
Control panel
Process Air Out-
let (optional duct
attachment kit
provided)
2. Tuck layflat
ducting (pur-
chased separate-
ly) through
square wire frame
and fold back
outside the frame.