TROUBLESHOOTING
F A U L T
Separate circuit
Unit not plugged into two sepa-
indicator light
rate circuits.
does not illumi-
Incorrect wiring in the building.
nate
Circuit breaker
Reactivation outlet not ducted.
trips after a few
Ducting is kinked or blocked.
minutes of opera-
Excessively long ducting.
tion.
Unit does not
Unit not switched on.
operate
No power to machine.
Not enough time to dry.
Unit operating,
Poor air movement in room.
but room not dry
Excessive moist air infiltration.
Room air is dry.
Unit removes too
Inlet air temperature is too warm.
little water
Inlet air temperature is too damp.
Filter is clogged.
If the problem you are experiencing is not listed here, call your local distributor or contact
our Service Department toll-free at 800-932-3030 for further assistance.
SPECIFICATIONS
Power
Amps (at 80°F/60%RH)
Process air
Reactivation air
Water removal
(at 80°F/60%RH)
Weight
Dimensions (W × H × D)
Air filter
Safety
C A U S E
115V / 60 Hz
Circuit 1: 12
Circuit 2: 12
395 CFM
65 CFM
118 pints/day | 55.8 L per/day
95 lbs. | 43.1 kg
21.14 × 33.13 × 20.25 in.
(With handle upright = 42. 250 in.)
53.7 × 84.15 × 51.4 cm
(With handle upright = 107.3 cm.)
3M HAF
ETL listed to CSA dehumidifier
standards
S O L U T I O N
Plug unit into two separate circuits rated for at least 15
amps each.
Locate a second 15 amp circuit in the structure.
The Reactivation Out must always be ducted.
Straighten all ducting as much as possible; remove any
blockages.
Length should not exceed 20 ft.
Switch unit on.
Check power cord connections at wall outlet and in top
compartment of unit. Check supply circuit breakers.
Allow more time for drying.
Increase evaporation with air movers.
Seal off area to reduce infiltration.
Confirm humidity level with hygrometer.
Decrease temperature of intake air.
Decrease humidity of intake air.
Check filter. Clean or replace as necessary.
PARTS INCLUDED
• Reactivation Out duct ring adapter
• Reactivation Out heat-resistant ducting, 20 ft., 6 in.
• 6 in. duct clamp
• Air inlet duct ring adapter (optional, installation requi-
red)
• Process air outlet layflat duct adaptor assembly (op-
tional, installation required)
• Two power cords, 25 ft. each
OPTIONAL
Layflat ducting for process air outlet (F536)
ADDITIONAL PRODUCT INFORMATION and current
documentation is available at http://DriTec.DriEaz.com.
FOR PARTS AND SERVICE CALL YOUR LOCAL
DISTRIBUTOR or Dri-Eaz at 800-932-3030.
www.dri-eaz.com