JOB HOURS
RESET? >
Press
to reset hours to zero. NOTE: When in
Humidistat mode, the unit will display HUMIDISTAT on
the top line during normal operation rather than JOB
HOURS.
LIFE HOURS
00 HRS
Shows total unit operating hours. Value cannot be
modified.
INLET
OUTLET
00° 00%
00° 00%
Shows current temperature and RH of inlet and outlet.
The HygroTrac system uses these values to calculate
grain depression.
HUMIDISTAT MODE
ON/OFF >
In ON mode, unit will maintain the humidistat setpoint
(see below). Press
to toggle between ON and OFF.
NOTE: When in Humidistat mode, the unit will display
HUMIDISTAT on the top line during normal operation
rather than JOB HOURS.
HUMIDISTAT
SETPOINT 00% >
Sets humidity level when unit is in Humidistat Mode (see
above). Press
to change RH value at 5% increments.
Settings cycle upward through 90%RH and start again at
30%RH.
TEMP UNITS
F° >
Shows current temperature scale. Press
Fahrenheit or Centigrade scale.
LANGUAGE
ENGLISH >
Shows current display panel language. Press
select Spanish, German, French or English.
COIL TEMP
00°F
Displays the cold (evaporator) coil temperature.
07-01674F 2011-04 Warranty 07-00420
Shows built-in wireless transmitter number. The
HygroTrac system uses this to uniquely identify your i-
Series unit. NOTE: For convenience, this same number
is shown on the barcode label affixed to the control
panel.
Press
TYPE, SENSOR REVISION, and SENSOR CONF REV.
A Dri-Eaz service technician may ask you for these
values when diagnosing a problem.
Shows compressor current draw in amps.
Error messages
If the i-Series onboard diagnostics discover a problem,
the unit will display an error message. If the unit is used
with the HygroTrac system, it will also transmit most
error messages to the user's HygroTrac website. See
"System Status and Data Messages" and "Error
Messages," p. 9, for a summary of messages.
At the end of the job
As with all dehumidifiers, once the drying job is
completed, it is important to make sure the unit is
completely purged of water before moving it. To ensure
that all water has drained into the pump, follow
these steps:
1. Turn the unit off and allow the plugged in dehumidifier
to rest for 10 minutes.
2. Press the PURGE key and while the purge pump is
operating, tip the unit back approximately 45° and hold
the unit in place. The manual purge cycle lasts
approximately 10 seconds.
3. Return the unit to the upright position and press
PURGE one more time to empty the pump.
Remove the dehumidifier promptly from the job site
once these steps have been completed.
to select
Before transporting, be sure to remove the external drain
hose, drain it carefully, and return it to the pocket
provided on the back of the unit.
MAINTENANCE
to
WARNING! ELECTRIC SHOCK HAZARD. Unplug the
dehumidifier before performing any maintenance.
Before each use
Inspect the electrical cord for damage. Look for
fraying, cuts, etc. Do not use the unit if you find any
damage. Call Dri-Eaz for the nearest Service Center at
800-932-3030.
Inspect and vacuum filter as needed. The i-Series
dehumidifiers are equipped with a 3M™ High Air-Flow
5
SENSOR ID >
00000000
to cycle through the following values: SENSOR
COMPRSSR CURRENT
0.0 A
Dri-Eaz Products, Inc.

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Lgr 3500iF410F411Lgr i serie

Table des Matières