Programmable Functions; 5.2 Description Of The Functions - Nice Mindy A6 Instructions Et Recommandations Pour L'installateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30

5.1) Programmable functions

With the FUNCTIONS dip-switch you can select the various functioning modes and add the functions required according to this table:
Switches 1-2: Off Off
On Off
Off On
On On
Switch 3
On
Switch 4
On
Switch 5
On
Switch 6
On
Switch 7
On
Switch 8
On
Switch 9
On
Switch 10
On
There is a second set of dip-switches with other functions in the A700F version:
Switch 11
On
Switch 12
On
Switch 13
On
Switch 14
On
Switch 15
On
Switch 16
On
Switch 17
On
Switch 18
On
Switch 19
On
Switch 20
On
We wish to remind you that the functions that are possible only in certain cases are indicated with the notes between the symbols "<>" fol-
lowing the description of the function.
Of course, if a dip-switch is "OFF" the function described will not be activated.
5.2) Description of the functions
Here is a brief description of the functions that can be added by
switching the relative dip-switch "ON".
Switches 1-2: Off Off = "Manual" movement (Man Present)
On Off = "Semiautomatic" movement
Off On = "Automatic" movement
On On = "Automatic+Always Closes" movement
In the "Manual" functioning mode, the gate will move only as long as
the key to command (it is held down).
In the "Semiautomatic" functioning mode a command pulse is
enough to carry out the whole movement up to the mechanical stop
or until the limit switch triggers. In the "Automatic" functioning mode
an opening manoeuvre is followed by a pause and then a closing
manoeuvre.
The "Always Closes" function comes into play subsequent to a tem-
porary power cut; if the gate is open a closing manoeuvre starts
automatically preceded by 5 seconds of preflashing.
Switch 3: On = Condominium function (not available in the Manual
mode)
In the Condominium functioning mode, once an opening manoeuvre
has started it cannot be interrupted by other command pulses on
STEP-BY-STEP or OPEN until the gate has finished opening. During
a closing manoeuvre, a new command pulse will stop the gate and
reverse the direction, opening the gate.
Switch 4: On = Preflashing
With a command pulse first of all flashing is activated followed by
movement 5 seconds later (2 seconds if on manual).
10
= "Manual" movement (Man Present)
= "Semiautomatic" movement
= "Automatic" movement (Automatic Closing)
= "Automatic+Always Closes" movement
= Condominium functioning mode < Not available in the Manual mode>
= Preflashing
= Recloses immediately after Photocell < Only in the Automatic mode>
= Photocell 1 also in Opening
= Gradual start
= Gradual stop
= Water hammering
= Courtesy light on flashing
= Positioning function < only with the aid of the limit switch >
= Flashing also in Pause < Only in the Automatic mode>
= Pressure holding
= Gate Open Indicator with proportional flashing
= Phototest operation
= Photocell and Photocell 1 also in opening
= Photocell and Photocell 1 at start of the opening manoeuvre
= Misses STOP in opening
= Misses STOP in closing
= CLOSE becomes PEDESTRIAN OPEN
(Automatic Closing)
Switch 5: On = Recloses straight after Photocell (only if in the Auto-
matic mode)
With this function the gate can be kept open only for the length of
time needed for transit; in fact, it will close automatically always 5
seconds after the last object has passed by the Photocell or Photo-
cell 1, irrespective of the programmed Pause Time.
Switch 6: On = Photocell 1 also in opening
This is the only function that makes the photoelectric cells PHOTO-
CELL and PHOTOCELL 1 different. As a rule the safety devices
PHOTOCELL and PHOTOCELL 1 will only trigger in the closing
manoeuvre, having no effect whatsoever in the opening manoeuvre.
If dip-switch No. 6 is turned "ON", the PHOTOCELL will continue
triggering only in the closing manoeuvre but PHOTOCELL 1 will trig-
ger also in the opening manoeuvre, causing an interruption in the
movement. In the semiautomatic or automatic mode, movement will
restart after the last object has passed by PHOTOCELL 1
This is useful to stop the gate in the opening manoeuvre when, for
example, a vehicle nears the gate from the inside, which is in the
direction of the manoeuvre, without stopping movement when the
vehicle nears the gate from the outside.
Switch 7: On = Gradual start
Movement starts gradually, sending an increasing force to the motor
forming a ramp that lasts about 1 second, this guarantees a jolt-free
start. (Not recommended on METRO gear motor).
Switch 8: On = Gradual stop
When movement finishes, a gradual stop is carried out, sending a
diminishing force to the motor with a decrement that lasts about 1
second, this guarantees a jolt-free stop.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Mindy a6fMindy a700f

Table des Matières