6) Programmable functions

The control unit features a set of microswitches and a selection
jumper that allow you to activate various functions designed to make
the system more suitable to the needs of users and more reliable
under different operating conditions. These functions are enabled by
setting the relevant dip-switch to ON; if the dip-switch is set to OFF
they are disabled.
1
10
Switch 1-2:
Off-Off
On -Off
Off-On
On -On
Switch 3:
On
Switch 4:
On
Switch 5:
On
Switch 6:
On
Switch 7:
On
Switch 8:
On
Switch 9:
On
Switch 10
On
Ponticello
Ponticello

6.1) Description of functions

Here is a brief description of the functions that can be added by setting the corresponding Dip-Switch to "ON".
Switch 1-2:
Off-Off
On-Off
Off-On
On-On
In the "Manual" operating mode, the gate will only move as long as the control button is held down.
In "Semiautomatic" mode, a command impulse will perform the whole movement until the Working Time limit expires or the limit stop is
reached. In the "Automatic" operating mode, an opening manoeuvre is followed by a pause, after which the gate closes automatically.
The "Always Close" function comes into play following a power failure; if the gate is not closed (FCC), a closing manoeuvre takes place, auto-
matically preceded by 5 seconds of pre-flashing.
Switch 3:
On
In the Condominium operating mode, once an opening manoeuvre has started it cannot be interrupted by other command pulses on "STEP-
BY-STEP" or "OPEN" until the gate has finished opening.
During a closing manoeuvre, a new command pulse will stop the gate and reverse the direction of movement in order to open the gate.
Switch 4:
On
A command impulse activates the flashing lamp followed by movement 5 s later (2 s later in the manual mode).
Switch 5:
On
This function, if in the Automatic mode, allows the gate to be kept open only for the time required for transit; when "PHOTO" finishes, the
manoeuvre stops. After 5 s a closing manoeuvre will automatically begin. In the Semiautomatic mode, the triggering of PHOTO during a clos-
ing manoeuvre will cause the re-opening of the gate followed by its automatic closing with adjusted pause time.
Switch 6:
On
The "Photo" safety device is normally active only during the closing manoeuvre; if Dip-Switch 6 is turned "On", the safety device will cause
the movement to stop also during the opening manoeuvre.
In the Semiautomatic or Automatic modes, the opening manoeuvre will start again immediately after the photocell has been disengaged.
Switch 7:
On
Starts the manoeuvre gradually, preventing the automatic system from being jolted.
Switch 8:
On
Deceleration reduces speed to 30% of rated speed in order to limit the force of the impact in the gate's opening and closing areas.
10
overhead garage door
sliding gate
= "Manual" movement, i.e. hand operated
= "Semiautomatic" movement
= "Automatic" movement, i.e. automatic closing
= "Automatic + always close" movement
= Condominium operation ( not available in manual mode)
= Pre-flashing
= Close 5" after Photo (in automatic mode) or Close after Photo (in semiautomatic mode)
= "Photo" safety also during opening manoeuvres
= gradual departure
= deceleration
= Brake
= Phototest
= overhead garage door
= sliding gate
= "Manual" movement (hand operated)
= "Semiautomatic" movement
= "Automatic" movement (automatic closing)
= "Automatic + Always Close" movement
= Condominium operating mode (not available in the Manual mode)
= Pre-flashing
= "Close" 5 s. after Photo (in the "Automatic" mode) or "Close" after Photo (in the "Semiautomatic" mode)
= Safety (Photo1) also during the opening manoeuvre
= gradual departure
= deceleration
!
Some of the programmable functions are linked to
safety aspects; carefully evaluate the effects of a function
and see which function will ensure the highest possible
level of safety.
The dip-switches allow you to select the various operating modes
and to activate the desired functions according to the table below: