10) Disposal

This product is made from various kinds of material, some of which
can be recycled. Make sure you recycle or dispose of the product in
compliance with laws and regulations locally in force.

11) What to do if...

This section will help fitters to solve some of the most common problems that may arise during installation.
No LED is on:
• Check whether the control unit is powered (check mains voltage is present at terminals 1-2 and a voltage of approx. 24Vac at terminals
10-11)
• Check the 2 mains fuses have not blown; if they have, replace them. If the malfunction persists a serious fault has probably occurred and
the control unit should therefore be replaced.
The OK LED flashes regularly but the INPUT LED's do not reflect the state of the respective inputs
• Carefully check the connections on input terminals 10÷20
Even if a command impulse is sent to the inputs the manouvre does not start
• Check that the LED's of the "STOP" (FCA + FCC) and "PHOTO" safety device are on and that the relative command LED that is activated
("STEP-BY-STEP, OPEN or CLOSE") remains on for the whole duration of the command.
• Check the connection of the constant resistance STOP input; the manoeuvre is enabled only if there is a voltage of 9 to 11 Vdc (corre-
sponding to a resistance of 6150 Ω to 10250 Ω) on terminals 21 – 22.
The gate changes direction during a manoeuvre
An inversion is caused by:
• Photocell triggering; in this case, check the connections of the photocells and check the input LED's.

12) Technical specifications

Mains power input
Adjustable force:
Motor output
Services voltage
Max current for 24 V services
Phototest output
Sensitive edge input
Flashing light output
Courtesy light output
"SCA" open gate telltale light output
Operating temperature
Working Time (sliding mode)
Working Time (overhead garage door mode)
Pause Time (TP)
Dimensions; Weight
Protection class
Nice S.p.a. reserves the right to modify its products without any notice
!
Some electric components may contain polluting sub-
stances; do not dump them.
: 230 Vac 50/60 Hz
version A100F
120 Vac 50/60 Hz
version A100F/V1
: 5 levels 30/45/60/80/100% with selector switch
: one 500VA (2.5A) motor or two 250VA (1.25A) motors connected in parallel
: 24 Vac ± 25%
: 200mA
: 100mA
: 8200 Ω ± 25% to enable the manoeuvre
: For flashing lights at mains voltage, maximum power 100 W
: For flashing lights at mains voltage, maximum power 100 W
: For 24 Vac telltale lights, maximum power 2 W
: -20 ÷ 50 °C
: Adjustable from 2.5 to >40 s, or from <40 to >80 s with TLM
: Adjustable from 2.5 to >20 s, or from <20 to >80 s with TLM
: Adjustable from 5 to >80 sec.
: 230 x 180 h100 mm ; 2110 g.