WHAT TO DO IF... (Troubleshooting)
• A detector occasionally generates an improper alarm:
– Check whether the batteries are dead .
– Check the detector for dirt and damp .
– Check the user instructions for the sensor in question for the causes of false
alarms and resolve the problem . If the false alarms persist, place a second
detector in the same area and associate it with the first one using the AND
function .
• A detector occasionally generates false tampering alarms
This may be due to temperature differentials deforming its housing surface .
Exclude the tamper device on the bottom of the housing with the provided
dipswitch .
HSDID11: Door/window open detector
- Incomplete closure: if the door/window is not perfect closed, it can be
moved by the wind .
- Deformation: check the distance between the sensor and magnet with the
door/window fully closed .
- Vibration: the break-in sensor is sensitive to strong vibrations .
- External contact: the external contact connection is sensitive to high levels
of damp .
HSDIM10: IR detector with volumetric lens
HSDIM12: IR detector with shutter lens
- Strong currents of hot/cold air: the IR sensor is sensitive to moving warm
bodies .
- Large insects: a hornet at a distance of 1 cm is perceived by the sensor like
an elephant at 10 m .
- Vibration: the break-in sensor is sensitive to strong vibrations .
- External contact: the external contact connection is sensitive to high levels
of damp .
HSDIS01: Combustion smoke detector (volatile fine particles)
- Cooking fumes and vapour: install the sensor away from cooking equip-
ment .
- Dust: do not install the sensor in a dusty environment .
HSDID01: Glass breakage sensor
- Falling objects: may generate sound similar to that of breaking glass .
- Rapid changes in air pressure: A/C equipment and fans may generate
false alarms when turned on .

Disposal of the product

All devices in the alarm system are an integral part of the installation and must
be disposed of as a whole . As in installation operations, at the end of the prod-
ucts' lifespan, decommissioning operations must be performed by qualified
personnel .
This product is made of various types of materials, some of which can be recy-
cled while others must be scrapped . Find out about recycling and disposal
systems in use in your area for this product category .
Caution! – Some parts of the products may contain polluting or hazardous
substances which, if released into the environment, may cause serious damage
to the environment or to human health .
As indicated by the adjacent symbol, it is strictly forbidden to dispose of these
products together with domestic waste .
Separate the waste into categories for disposal, according
to the methods established by current legislation in your
area, or return the products to the retailer when purchasing
a new version .
Caution! – Local regulations may provide for heavy fines if
these products are disposed of inappropriately .
32 – English
HSDIW01: Flooding detector
- Condensation or high humidity: high humidity may result in condensation
forming on the sensor .
- Dirt: dirt increases the risk of tripping by high humidity .
• When I move in front of a volumetric sensor, it does not trip: volumetric
detectors do not retransmit their alarms within 3 minutes of the first occurrence .
Wait for at least 3 minutes and try again .
• All Nice Home Security system products
Nearly all products are protected against opening and removal; the areas of
attack are usually the cover and base of the device . Improper mounting and
closure of the covers can trip a false alarm; this may be intermittent, for exam-
ple during large changes in temperature .
• If the control panel emits a continuous beep when turned on
- Check that the memory is inserted correctly . Remove and insert the SIM
again .
- Check that the SIM card is properly inserted . Remove and insert the SIM
again .
- PIN Activated . Unplug and remove the SIM and disable the PIN request with
a mobile phone .
- Make sure that the SIM has not expired .
• Problems with the dialler test
To run the dialler test, you must have first programmed the voice and SMS
messages .
- If the GSM call is not completed successfully, there may be problems with the
GSM coverage; if so, use a different operator or install the control panel in a
position with better coverage .
- If the PSTN call is not completed successfully (including ADSL), the cause
may be a phone line disturbance: in this case, to force the call, prefix the
number with the symbol Q, by pressing p (e .g .: Q9876543) .
DISPOSAL

Disposal of batteries

Caution! – The batteries used in this alarm system, even when dis-
charged, contain polluting substances and therefore must not be dis-
posed of as household waste. Dispose of according to separate waste
collection procedures as envisaged by current local standards.