Special Functions; What To Do If - Nice Moon MC824H Instructions Et Avertissements Pour L'installation Et L'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
L8
List of
L1
faults
L2
L3
L4
L5
L6
L7
L8
Note – The factory settings are highlighted in grey.

5.3 - Special functions

5.3.1 - Function: "Move anyway"
This function allows the automation to be operated even when any of the safe-
ty devices does not work correctly or is out of use.
The automation can be controlled in the "hold-to-run" mode. Proceed as follows:
01. Send a command to operate the gate using a transmitter or a key selector,
etc. If everything operates correctly, the gate will move normally, otherwise
proceed as follows;
02. within 3 seconds, activate the control again and keep it activated;
03. after approximately 2 seconds, the gate will perform the required movement
in "hold-to-run" mode; i.e. the gate will continue to move only as long as
the control is activated.
If the safety devices do not operate, the flashing light flashes a few times to indi-
cate the kind of problem (see chapter 6 - Table 10).
5.3.2 - Function: "Maintenance warning"
This function serves to indicate when the automation requires maintenance.
The maintenance warning signal is given by way of a lamp connected to the
S.C.A. (open gate light) output when this output is programmed as "Mainte-
nance light". The various warning lamp signals are shown in Table 9.

WHAT TO DO IF...

6
(troubleshooting guide)
Some devices are able to emit signals that serve to recognise their state of
operation or possible faults.
If a flashing light is connected to the FLASH output on the control unit, it will
Flashes
1 short flash
1 second pause
1 short flash
2 short flashes
1 second pause
2 short flashes
3 short flashes
1 second pause
3 short flashes
4 short flashes
1 second pause
4 short flashes
5 short flashes
1 second pause
5 short flashes
6 short flashes
1 second pause
6 short flashes
7 short flashes
1 second pause
7 short flashes
8 short flashes
1 second pause
8 short flashes
9 short flashes
1 second pause
9 short flashes
10 short flashes
1 second pause
10 short flashes
Manoeuvre 1 result (most recent)
Manoeuvre 2 result
Manoeuvre 3 result
Manoeuvre 4 result
Manoeuvre 5 result
Manoeuvre 6 result
Manoeuvre 7 result
Manoeuvre 8 result
TABLE 10 - Flashing light signals (FLASH)
Problem
Bluebus system error
Photocell activated
Function activation
"Obstacle detection" by force limiter
STOP input activation
Error on internal parameters in
control unit
Maximum limit of consecutive mano-
euvres or manoeuvres per hour excee-
ded.
Electric circuits fault
A command is already present
that disables execution of other
commands
The automation has been blocked by
a "Block automation" command
"Obstacle detection" by encoder
function activated
To program the limit value of the maintenance operations, see Table 8.
Table 9 - "Maintenance light"
Number of manoeuvres Signal
Below 80% of the limit
Light on for 2 seconds at the start of the opening
manoeuvre.
Between 81% and
Light flashing for the entire duration of the manoeuvre.
100% of the limit
Beyond 100% of the limit
Light flashing continuously.
5.4 - Deleting the memory
To delete the control unit memory and restore all factory settings, proceed as
follows:
press and hold keys " " and " " until leds L1 and L2 start flashing.
flash at intervals of 1 second during a manoeuvre. If faults occur, the flashing
light will emit a sequence of two shorter flashes separated by a 1 second
pause. Table 10 shows the cause and solution for each type of signal.
The LEDs on the control unit also emit signals.
Table 11 shows the cause and solution for each type of signal.
It is possible to verify faults that have occurred during the last 8 manoeuvres.
See Table 12.
Solution
At the start of the manoeuvre, the devices connected to Bluebus do not
correspond to those recognized during the self-learning phase. One or
more devices may be disconnected or faulty; check and, if necessary,
replace them. In case of modifications repeat the device self-learning pro-
cess (see paragraph 3.4).
One or more photocells do not enable movement or have caused a move-
ment inversion during travel; check to see if there are any obstructions.
During the movement, the motors encountered excessive resistance;
identify the cause and if necessary increase the level of force of the
motors.
At the start of the manoeuvre or during the movement, the STOP input
was activated; identify the cause.
Wait at least 30 seconds, then try giving a command and if necessary turn
off the power supply. If the condition persists, there may be a malfunction
and the electronic board must be replaced.
Wait a few minutes until the manoeuvre limiting device falls to below the
maximum limit.
Wait at least 30 seconds, then try sending a command and if necessary
turn off the power supply. If the condition persists, there may be a malfun-
ction and the electronic board must be replaced.
Check the type of command that is always present; for example, it could
be a command from a timer on the "open" input.
Release the automation by giving the "Automation release" command.
During the movement, the motors have been blocked by higher friction;
identify the cause.
The type of fault that has occurred in
the last 8 manoeuvres can be establi-
shed
See TABLE 12 – Fault log.
English – 7

Publicité

Table des Matières
loading

Table des Matières