LED
BLUEBUS
Always off
Always on
1 flash per second
2 quick flashes
Series of flashes separated by
one second pause
STOP
Always off
Always on
S.S.
Always off
Always on
OPEN
Always off
Always on
CLOSE
Always off
Always on
L1 - L2
Slow flashing
L3 - L4
Slow flashing
01. Press and hold down the "Set" key for approx. 3 seconds;
02. Release the key when LED "L1" starts flashing;
03. Press keys " " or " " to move from the flashing LED to L8 LED ("input LED") for the "Fault log" parameter;
04. Press and hold the "Set" key through to completion of point 06;
05. Wait approx. 3 seconds until the LEDs representing the levels corresponding to the manoeuvres with faults illuminate.
The LED L1 indicates the result of the most recent manoeuvre while L8 indicates the eighth-to-last manoeuvre.
If the LED is on this means that a fault has occurred; if the LED is off, everything is normal;
06. Press keys " " and " " to select the required manoeuvre: the corresponding LED performs a number of flashes equal
to those normally performed by the flashing light;
07. Release the "Set" key.
7

FURTHER DETAILS

The following optional accessories are available for the control unit MC824H:
SMXI, OXI family receivers, Oview programmer, the Solemyo solar energy pan-
el and the PS324 buffer battery.

7.1 - Connecting a radio receiver

The control unit has a connector for connecting radio receivers (optional acces-
so ries) belonging to the SMXI and OXI families. To connect a receiver, discon-
nect power from the control unit and proceed as shown in fig. 8. Table 13 and
Table 14 show the commands corresponding to the outputs on the control unit.
SMXI / SMXIS or OXI / OXIFM / OXIT / OXITFM in mode I or Mode II
Output no. 1
"S.S." (Step by Step) command
Output no. 2
"Partial opening 1" command
Output no. 3
"Open" command
Output no. 4
"Close" command
8 – English
TABLE 11 - Signals given by LEDs on control unit (fig. 7)
Problem
Fault
Serious fault
Everything normal
Input status variation
Various
Activation of the devices connected
to the STOP input
Everything normal
Everything normal
S.S. input activation
Everything normal
OPEN input activation
Everything normal
CLOSE input activation
Change in number of devices
connected to Bluebus or device
self-learning not performed
Change in self-learning of the motor
types or the positions of the mechani-
cal stops
Table 13
Solution
Check that the control unit is powered. Check that the fuses have not
blown: if they have, check the cause of the fault and replace with others
with the same value
A serious fault has occurred: try disconnecting electrical power from the
control unit. If the problem persists it will be necessary to replace the
electronic board
Control unit works correctly
Normal if one of the inputs (PP, STOP, OPEN, CLOSE) changes: photocells
activated or a command given via a transmitter
Refer to Table 10
Check the devices connected to the STOP input
STOP input active
S.S. input not active
Normal if the device connected to the S.S. input is active
OPEN input not active
Normal if the device connected to the OPEN input is active
CLOSE input not active
Normal if the device connected to the CLOSE input is active
The device self-learning process must be performed
(see paragraph 3.5)
Self-learning of the mechanical stop positions has not been performed
TABLE 12 - Fault log
OXI / OXIFM /OXIT / OXITFM in extended mode II
No.
Command
1
Step by step
2
Partial opening 1
3
Open
4
Close
5
Stop
6
Apartment block
Step by Step
7
Step by Step
high priority
8
Partial open 2
9
Partial open 3
10
Open and block
automation
SET
L1
o
SET
3 s
e
SET
Table 14
Description
"S.S." (Step by Step) command
"Partial opening 1" command
"Open" command
"Close" command
Stops manoeuvre
Apartment block control
Gives command even when automation is blocked
or commands are in progress
Partial open (Opening of leaf M2 to 1/2 of normal opening)
Partial open (Opening of two leafs to 1/2 of normal opening)
It causes an opening manoeuvre, after which the automa-
tion is blocked; the control unit accepts no further com-
mands with the exception of "Step by step high priority",
"Release" automation and (from Oview only ) the com-
mands "Release and close" and "Release and open"