Description Of Connections - Nice mindy A100F Instructions Et Recommandations Pour L'installateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26
2.3.1) Wiring diagram
F1
MAX
1 2
3
4
5
6
MIN
FORCE
L
N
2.3.2) Description of the connections
The following table provides a brief description of the possible control unit output connections.
Terminal
Functions
1-2
Power supply
3-4
Flashing light
5-6
Courtesy Light
7-8-9
motor
10-11
24 Vac
12
Phototest
13
Common
14
A.C. Light
15
OPEN limit switch
16
CLOSE limit switch
(15-16)
Stop
17
Photo
18
Step-by-step
19
Open
20
Close
21-22
constant resistance Stop
7
8
9
10 11 12 13
M1
Description
mains power supply line
Output for connecting flashing light to mains voltage (Max. 100W)
Output for connection of a mains voltage lamp (Max 100W)
motor output (Max 500VA)
24 Vac services power supply: Photo, Radio, ecc. (Max. 200mA)
Phototest output: power supply to photocell transmitters (Max. 100 mA)
Common for all inputs
24 Vac output for open gate indicator light (Max. 2W)
Input for connection of the OPEN limit switch.
Input for connection of the CLOSE limit switches.
The "Stop" input is obtained by connecting an NC-type contact serially with the limit switches
(see wiring diagram).
Input for safety devices with NC contact (e.g. photocells)
Input for cyclic command (OPEN – STOP – CLOSE – STOP)
Input for opening function (OPEN – STOP – OPEN)
input for closing command (CLOSE – STOP – CLOSE)
Input for "constant resistance Stop" 8.2kΩ (e.g. sensitive edge)
F2
OK
14
15
16
17
18
19
20
TL
21
22
Radio
receiver
AERIAL
TP
OVERHEAD
GARAGE DOOR
SLIDING GATE
GB
5

Publicité

Table des Matières
loading

Table des Matières