Télécharger Imprimer la page

Bauer S-BAR Instructions Et Avertissements Pour L'installation Et L'utilisation page 12

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 42
01. Press and hold down the "Set" key for approx. 3 seconds;
02. Release the key when LED L1 starts flashing.
03. Press keys "s" or "t" to move from the flashing led to led L7;
04. Press and hold the "Set" key through to completion of point 07;
05. Wait approx. 3 seconds, until the LED representing the current level of the "Maintenance Notification" illuminates;
06. Press and immediately release the "s" or "t" keys;
07. The led corresponding to the selected level shows a series of flashes. to indicate that the manoeuvre counter has
been reset. The number of flashes indicates the percentage of the set limit of manoeuvres performed (as multiple of 10%).
Example: when the maintenance notification is set on L7 (40000), 10% corresponds to 1000 manoeuvres;
if the indicator led flashes 4 times, this means that 40% of the manoeuvres have been completed (between 4000 and
4999 manoeuvres).
If at least 10% of the manoeuvres has not yet been reached, no flashes are emitted;
08. Release the "Set" key.
01. Press and hold down the "Set" key for approx. 3 seconds;
02. Release the key when LED L1 starts flashing.
03. Press keys "s" or "t" to move from the flashing LED to L7 LED ("input LED" for the "Maintenance Notification" parameter);
04. Press and hold the "Set" key through to completion of point 07;
05. Wait approx. 3 seconds, until the LED representing the current level of the "Maintenance Notification" illuminates;
06. Press and hold keys "s" and "t" for at least 5 seconds, then release. During this phase the led corresponding to the
selected level shows a series of quick flashes to indicate that the manoeuvre counter has been reset;
07. Release the "Set" key.
• Fault log
This function enables display of any faults occurring during the last 8 manoeu-
vres, such as an interruption to a manoeuvre caused by activation of a photo-
01. Press and hold down the "Set" key for approx. 3 seconds;
02. Release the key when LED L1 starts flashing.
03. Press keys "s" or "t" to move from the flashing LED to L8 LED ("input LED" for the "Fault log" parameter);
04. Press and hold the "Set" key through to completion of point 06;
05. Wait approx. 3 seconds until the LEDs representing the levels corresponding to the manoeuvres with faults illuminate.
Led L1 indicates the result of the most recent manoeuvre, and led L8 indicates the result of the eighth manoeuvre; if a led
is lit, this means that one or more faults have occurred during the manoeuvre; if off this means that the manoeuvre has
been completed correctly.
06. Press keys "s" and "t" to select the required manoeuvre: the corresponding LED performs a number of flashes equal to
those normally performed by the flashing light after a fault occures (see Table 15);
07. Release the "Set" key.
TABLE 10
TABLE 11
cell or a sensitive edge. To check the list of faults, proceed as described in
Table 12.
TABLE 12
SET
3 s
L1
SET
or
L7
SET
3 s
and
x 1 = 10-19%
x 2 = 20-29%
x 3 = 30-39%
x 4 = 40-49%
x 5 = 50-59%
x 6 = 60-69%
x 7 = 70-79%
x 8 = 80-89%
x 9 = 90-99%
x 10 = > 100%
SET
SET
3 s
L1
SET
or
L7
SET
and
SET
SET
3 s
L1
SET
or
L8
SET
3 s
and
SET
English – 11

Publicité

loading