Input LED
Parameter
LED (level)
L1
Time
L1
Pause
L2
L3
L4
L5
L6
L7
L8
L2
Function
L1
Step by
L2
step
L3
L4
L5
L6
L7
L8
L3
Speed
L1
Motor
L2
L3
L4
L5
L6
L7
L8
L4
Output
L1
FLASH
L2
L3
L4
L5
L6
L7
L8
L5
Motor force
L1
on opening
L2
L3
L4
L5
L6
L7
L8
L6
Motor force
L1
on closure
L2
L3
L4
L5
L6
L7
L8
L7
Mainte-
L1
nance
L2
warning
L3
L4
L5
L6
L7
L8
L8
List of
L1
faults
L2
L3
L4
L5
L6
L7
L8
Note – Grey colour represents the factory setting.
- Do not set an excessively high value for the "motor force" as this may impair operation of the safety system or damage the pole;
- If the "Motor force control" is used in support of the system for impact force reduction, after each adjustment the force measurement procedure must be performed, as envisaged
by standard EN 12445.
- Wear and atmospheric conditions influence movement of the pole; motor force settings should be checked periodically.
TABLE 7 - Second level functions
Value
5 seconds
10 seconds
20 seconds
40 seconds
60 seconds
80 seconds
120 seconds
200 seconds
Open – stop – close - stop
Open – stop – close - open
Open – close – open - close
Apartment block (more than 2 sec. generates Stop)
Apartment block 2 (less than 2 sec. generates partial opening).
Step by step 2
Hold-to-run
Opening in semi-automatic mode, closing in dead man mode
Speed 1 (30% - slow)
Speed 2 (47%)
Speed 3 (65%)
Speed 4 (82%)
Speed 5 (100%) - fast
Open V3, Close V2
Open V4, Close V3
Open V5, Close V4
Pole Open Indicator Function (24 V - 10 W)
Active if pole closed (24 V - 10 W)
Active if pole open(24 V - 10 W)
Flashing light(12 V - 21 W)
Flashing light for pole lights (24 V - 10 W) - always flashes
Electric lock(24 V - 10 W)
Suction cup(24 V - 10 W)
Maintenance indicator (24 V - 10 W)
Force 1 (low)
Force 2
Force 3
Force 4
Force 5
Force 6
Force 7
Force 8 (high)
Force 1 (low)
Force 2
Force 3
Force 4
Force 5
Force 6
Force 7
Force 8 (high)
2500
5000
10000
15000
20000
30000
40000
50000
Manoeuvre 1 result (most recent)
Manoeuvre 2 result
Manoeuvre 3 result
Manoeuvre 4 result
Manoeuvre 5 result
Manoeuvre 6 result
Manoeuvre 7 result
Manoeuvre 8 result
WARNINGS:
Description
Sets the pause time, i.e. the time that
passes between the end of an ope-
ning manoeuvre and the start of an
automatic closing manoeuvre
This parameter is only effective if the
"automatic Closure" is active.
Sets the sequence of commands as-
sociated with the input or the radio
control: "Step by step".
Sets the motor speed during normal
travel.
Selects the type of device connected
to the FLASH output.
Important! – If the programmed set-
ting is modified, check the type of vol-
tage of the new device connected to
the FLASH terminal and ensure that it
corresponds to the type of voltage of
the selected programming level.
Adjusts the motor force control sy-
stem to adapt it to the weight of the
pole during the opening manoeuvre
and consequently the sensitivity of
obstacle detection.
Note – The force is acquired auto-
matically during execution of the first
two manoeuvres.
Adjusts the motor force control sy-
stem to adapt it to the weight of the
pole during the closing manoeuvre
and consequently the sensitivity of
obstacle detection.
Note – The force is acquired automa-
tically during execution of the first two
manoeuvres.
When the FLASH output is program-
med as a maintenance indicator: this
sets the maximum number of mano-
euvres to be performed, after which
the signal is sent to notify of the need
for automation maintenance.
The type of fault that has occurred in
the last 8 manoeuvres can be establi-
shed (see: paragraph 8.2 - malfunction
event log and Table 14).
A detailed log can be stored of all events
on S-BAR (and other devices connec-
ted on the network) by connecting the
Oview programmer