Broncolor Scoro Serie Mode D'emploi page 22

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

13. SCORO S
ADDITIONAL FUNCTIONS & LISTING IN LCD MAIN MENU
Section
Function
13.0
WiFi
13.1
Lamp outlets 1-3
13.2
Modelling light
13.3
Sequence (seq)
13.4
t 0.1 (flash duration)
13.5
Colour temperature
13.6
Interval (int)
13.7
Delay (dly)
13.8
Freemask (fm)
13.9
Alternate (alt)
13.10
Aux. backup
22
Description of function
WiFi settings
Display of the activated lamp outlets in joules or percentage.
Choice of the modelling light level. See section 5.1.
Allows to define a flash series or the pre-selection of a defined
number of flashes to be triggered together with the shortest
possible intervals; provided that the "interval" function is not
activated. After the flash series has been triggered, the photo-
cell becomes deactivated. To prevent overheating after extended
flash series (to protect the flash tubes), the unit will automa-
tically shut off.
Choice of flash duration t 0.1. The setting range is dependent on
the selected power.
Selection of colour temperature adjustment with simultaneous
display of flash duration (see 13.4), on the main page. The setting
range is dependent on the selected power.
Allows to define the time between each flash. By briefly pressing
the +/– keys, the setting is effected in 0.01 s steps. Prolonged
pressure alters the values in 0.1 – 2 s steps. 50 s are the maxi-
mum for intervals.
Delay triggering, this can be delayed in the range of 0.01s – 50.00 s.
If 2 units are selected in the freemask menu: By asynchronous
flashing with two power packs, an object can be isolated. For
this purpose, one of the power packs must be set on "active", the
other one on "wait". Hence, it is possible to make quasi two same
pictures within a very short time while having set the correct
camera shutter speed.
If more than 2 units are selected in the freemask menu:
"ping-pong release" of up to 4 power packs. Here, using up
to 4 power packs, you can determine the triggering sequence of
these power packs, i.e. only one power pack is triggered per
flash trigger signal while the others are waiting, or are being
recharged. This function realises even faster flash sequences.
Auxiliary backup stores additional functions (sequence, flash
duration t 0.1, colour temperature, interval, delay and alternate)
when switching off or in case of a power grid cut.