4.1 Meaning of the digital displays (11)
Example with energy level "8.7":
" 8.7 " blinks flash monitor has detected a misfire
>
"—"
lamp connected but switched off
>
" "
>
no lamp connected
"-o"
no energy allocation possible
>
(the entire energy has already been used up by other lamps)

5. MODELLING LIGHT

The "mod" key (15) switches on the modelling lamp for all connected lamps. When switched on,
the blue LED next to the "mod" key lights up. The lamps have also an additional modelling lamp
switch. Furthermore, it is possible to operate the modelling light proportionally (section 6.1) and
adapt it to the various maximum outputs of broncolor power packs.
Pressing the "mod" key (15) (for 1 s) when the modelling lamp is on, will give direct access to the
"full" mode. To return to the previous mode briefly press "mod" again.
Attention: Please ensure that the modelling lamp voltage corresponds with the local mains
(AC-line) voltage.
5.1 Proportionality
The modelling light brightness can be set proportionally to the flash intensity.
Stages prop1, prop2, prop3, prop4 and prop5 are used to adapt the modelling light brightness of
power packs with different output. The setting "modelling light proportional" duly allows for the
output set, the number of lamps as well as a possible asymmetrical energy distribution of the
Scoro power packs.
Proportionality is guaranteed if the identical operating mode has been set for all power packs. The
higher the digit, the brighter the modelling light.