8. DISPLAYS VISUAL | AUDIBLE
8.1 The visual ready signal
This is the blue LED at the "test" key or ready display (16). It lights
up only when the unit is fully charged or discharged. After triggering
a flash, this LED goes out, and lights up again when the unit is fully
charged once more.
The visual ready signal is easy to read even from larger distances. The
brightness (dark / bright) can be altered by the user (see LCD menu
"Brightness test" section 13.16)*.
8.2 The audible ready signal
An acoustic signal (beep) sounds when the power capacitors are 100 % charged, or discharged. The
signal may be switched on or off, and the volume may be regulated*. The corresponding setting
options are explained in LCD menu "Audio ready signal" (section 13.17).
When Scoro power packs are assigned an individual address, the acoustic signal can be pro-
grammed with an individual acoustic (beep) tone*.
8.3 Visual fault signal
In case of a technical fault or activation of the flash monitoring, the test
release key / ready signal (16) lights up red. Should the lamp plug not
be correctly engaged, this will be indicated by the red test release key
and the blinking digital display of the corresponding channel (11).
At the end of their service lives, flash tubes often misfire. This fault is
indicated by the test release key of the Scoro power packs that lights
up red. Additionally, the digital display (11) of the channel to which the
lamp concerned is connected, blinks.
Attention: Check to see if the flash tube is in working order, and change if necessary.
The blinking digital display of the channel concerned can be deactivated by pressing the key "lamp
connection on / off" (7.1, 7.2, 7.3*).
If the fault indication is not caused by the lamp, the power pack must be switched off and on again.
Should the test release key remain red, please contact a broncolor service station.
8.4 Audible fault signal
When the flash discharge fails, a warning signal (two-sound tone) of approx. 0.5 s duration will
sound and the display (11) of the relevant lamp will flash.