5. - Installation
5.1
5.2
5.3
5.4
5.5
5.6
5.7
5.8
5.9
*) For BADU Jet
active: attach hose
5.10
directly to the con-
verter situated in
the terminal box of
the pump motor
5.11
5.12
For the safety of
the swimmers do
not operate the
5.13
unit without hou-
sing cover!
**) Tighten the
screws only by
hand. Do not use
force!
45
Select mounting site and prepare in accordance with page 22 fi g. 17.
For BADU Jet active see page 24 fi g. 20. When the unit is installed on an
aboveground pool, the telescoping safety support must be used. See
page 23 fi g. 18. For BADU Jet active see page 24 fi g. 19.
Make sure the shipment contains all parts enumerated in the packing list.
Place unit on the pool edge and mark mounting holes.
Remove unit again, drill holes of 10 mm diameter at markings.
Insert brass expanding bolt (25) and fasten bonded metal (rubber metal)
buffer (26), see page 17 fi g. 10.
Make sure that the bolts are securely anchored in the base plate so that
the unit will be totally stable.
Place unit onto bonded-metal buffers and fasten by means of hex bolts
(32) with lock washers (31) plus another washer (30), see page 17 fi g.10.
By equalizing the distance, the actual distance between the unit housing
and the pool edge is adjusted. This will result in added stability for the
unit.
Plug in woven-fabric fl exible tubing (6), 14 mm dia., for air-intake onto
the hose tail of the air regulator and fasten by means of clamp (18), see
page 17 fi g. 7. The connection is located inside the housing.
Push plastic tubing (36), page 17 fi g. 7, dia. 3 x 1,5 mm from the
pneumatic pushbutton onto the hose tail of the pressure converter at the
control box.*
Before connecting the power supply, please carefully read part 7,
"Electrical Connection", and part 8, "Electrical Connection at Installation
Site".
Connect power supply in accordance with Part 7, "Electrical Connection"
ATTENTION! This is important! When you put the cover back in its
place, make sure that it snaps snugly into place over the position switch.
Fasten the cover securely to the base plate**. The position switch is now
activated, the circuit is closed and the unit is ready to function.
Connect the safety-catch of the housing with the housing unit, see
page 17 fi g. 9.
09.05.2007 TB-b BTA_einhaengeanlagen_v2_engl.indd