Emerson VOLTA CF590BQ00 Mode D'emploi page 24

Ventilateur de plafond pour environnement humide de 54 po
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

13. Light Kit LED Driver Replacement
13.2
Remove the two knurled knobs and lockwashers from the
threaded studs. Retain the hardware for future
reinstallation (Figure 41).
Slide the ceiling cover downward to rest on top the motor
housing.
13.3
Slide the receiver out of the hanger bracket for
disassembly of the wiring.
Removal of the Ceiling Fan Wires, See Section 7,
Reverse Steps 7.6 through 7.1.
Retain all hardware for future reinstallation.
13.4
Carefully remove the ceiling fan (hangerball / downrod)
from the hanger bracket.
Place the ceiling fan, downrod facing up, onto a secure
solid surface in preparation of the driver replacement.
NOTE: Be very careful not to bend the blade
assemblies while removing the ceiling fan.
13.5
Remove the hanger ball pin from the hanger ball to release
the hanger ball from the downrod (Figure 43).
Loosen the Phillips head setscrew to release the hanger
ball from the downrod (Figure 43).
Retain both the pin and hanger ball for future reinstallation.
Figure 41
WIRE CONNECTOR
Figure 42
4.5" DOWNROD
PHILLIPS HEAD
SETSCREW
Figure 43
24
(Continued)
CEILING
COVER
THREADED
STUDS (2)
LOCKWASHERS (2)
KNURLED
KNOBS (2)
OUTLET BOX
RECEIVER
PIN
HANGER
BALL
ETL Model No.: CF590

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Volta cf590grt00Volta cf590pt00Volta cf590sw00Cf590bq00Cf590pt00Cf590sw00

Table des Matières