Emerson VOLTA CF590BQ00 Mode D'emploi page 17

Ventilateur de plafond pour environnement humide de 54 po
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7. How to Wire Your Ceiling Fan
7.6
Securely connect the receiver blue wire (TO LIGHT) to the
fan motor blue wire using the wire connector (supplied in
parts bag) (Figure 29).
7.7
While inserting the receiver fully into the hanger bracket,
turn leads upward and carefully push leads into the outlet
box, with the white and green leads on one side of the
outlet box and position the black lead on the other side of
the outlet box (Figure 30).
WARNING
!
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.
7.8
Screw the two threaded studs (supplied in parts bag) into
the tapped holes in the hanger bracket (Figure 31).
FAN MOTOR BLUE WIRE
Figure 29
Figure 30
Figure 31
17
(Continued)
RECEIVER
BLUE WIRE
(TO LIGHT)
OUTLET BOX
RECEIVER
HANGER BRACKET
HANGER BRACKET
THREADED STUDS (2)
emersonfans.com
Please contact 1-800-654-3545 for further assistance
ETL Model No.: CF590