Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

When battery power reaches 2,3V for NOVA Wi-Fi and 3V for TOUCH Wi-Fi, these safeties
signal to MASTER Wi-Fi FR the low battery status and MASTER Wi-Fi FR activates the buzzer
with a sound every 3 seconds for 1 minute.
The warning is renewed for 1 minute if a new command is received.
The LED EDGE PHOT paired to the photocell or the strip with the low batteries, emits a
steady red light.
The system is still operational, but it is better to replace the batteries as soon as possible in
order to avoid a full stop of the door operation which happens when the batteries reach 2V
for NOVA Wi-Fi/VERTIGO Wi-Fi and 2,7 V for TOUCH Wi-Fi.
ALARM (batteries empty or safety damaged)
The alarm activates when the batteries are empty (2V for NOVA Wi-Fi/VERTIGO Wi-Fi and
2,7V for TOUCH Wi-Fi) or when a safety is damaged.
On MASTER Wi-Fi FR the LEDs DL1, DL2 and DL3 turn off and MASTER Wi-Fi FR blocks
the automation.
On MASTER Wi-Fi the LED EDGE PHOT paired with the photocell or the strip damaged, or
with the low batteries, flashes red. The BUZZER emits a sound every 3 seconds for 1 minute,
notifying the user to change the batteries or call a technician to repair the safety.
The alarm is renewed for 1 minute if a command is given to the door.
REPLACING THE BATTERIES
The lifespan of the 1.5 V AA batteries used in the safety devices is about 3 years.
In case it is required to replace the batteries, it will not be necessary to re-program the
devices.
- Identify the safety device with empty batteries by checking LEDs EDGE PHOT.
- Using the number of LED EDGE PHOT which is flashing red or that emits a steady red light,
identify the number of the safety device with batteries empty.
- Find the NOVA Wi-Fi or TOUCH Wi-Fi devices with the yellow sticker bearing the
identification number corresponding to the number of the LED EDGE PHOT which is in
alarm status on the MASTER Wi-Fi FR.
- Replace the batteries, checking that the polarity is correct.
- Press push button PROG TX on the NOVA Wi-Fi or TOUCH Wi-Fi to restart the MASTER
Wi-Fi FR.
- The buzzer of the MASTER Wi-Fi FR will turn off and the LEDs DL1-DL2-DL3 (if in alarm
status) will turn on. The LED EDGE PHOT corresponding to the safety device with the new
batteries will turn off.
The automation is now ready to restart.
ATTENTION: Please remember that batteries must be disposed properly according to current
standards. In case of disposal of the safety devices, please remember to remove the AA
batteries and dispose them properly
PROCEDURE TO DELETE ALL RECORDED SAFETY DEVICES
To delete all safety devices recorded in the MASTER Wi-Fi OS memory, just push and hold
the button PROG. RX for 10 seconds.
After 10 seconds all LEDs EDGE PHOT will flash 6 times, indicating successful removal.
Afterwards LED EDGE PHOT and LEDs DL1, DL2 and DL3 will turn off.
ATTENTION: WITH LED DL1, DL2 AND DL3 OFF, AUTOMATION DOES NOT WORK.
PROCEDURE TO DELETE A SINGLE SAFETY DEVICE
In order to remove a single safety device, use the following procedure:
- Push PROG. RX one or more times to select the LED EDGE PHOT, to select the safety device
to delete, which begins flashing green.
- After selecting the safety device, push and hold the button PROG. RX for 10 seconds.
- After 10 seconds LED EDGE PHOT flashes red/green 6 times, indicating successful
removal.
ATTENTION: Place the DIP EDGE PHOT paired to the deleted safety device in OFF, then
scan all LEDs EDGE PHOT pushing the button PROG. RX 6 times.
IMPORTANT: Remove batteries from the deleted safety device.
H -
PROGRAMMING REMOTE CONTROLS FOR TOTAL OPENING
(100 codes maximum)
Using the following procedure it is possible for MASTER Wi-Fi FR to memorize the following
remote controls:
SUN 2-CHANNEL 433 MHz
SUN 4-CHANNEL 433 MHz
SUN CLONE 2-CHANNEL 433 MHz
SUN CLONE 4-CHANNEL 433 MHz
As MASTER Wi-Fi FR turns on, yellow LED DL6 will turn on. At the same time the buzzer will
emit a tone indicating proper power status.
a - If MASTER Wi-Fi FR memory is empty (by factory) LED DL7 flashes red/green.
b - If codes are already present in the memory, LED DL7 remains off (perform what is
described on paragraph PROCEDURE TO DELETE ALL CODES).
In addition to the codes, MASTER Wi-Fi FR also learns the channels that are desired
for use. Be careful to remember the buttons pushed on the remote controls during
the code memorization procedure as they will be those used thereafter for the total
opening.
If no code is sent, after 10 seconds the red LED DL7 turns off indicating the end of the
programming procedure.
- Push and hold the button PROG RX for at least 3 seconds. After release LED DL7 flashes
red for 10 seconds.
- At this time pressing one of the buttons on the transmitter will memorize the code.
Successful code memorization is shown by LED DL7 which emits a green light for 500ms
and by a tone from the buzzer, indicating successful memorization.
- After memorizing the first code, the memorization time resets for 10 seconds and it is
possible to memorize more codes.
To finish the code memorization procedure, allow 10 seconds to pass until the flashing red
LED DL7 turns off. Alternatively, push button PROG RX on the MASTER Wi-Fi FR. Also in this
case the flashing red LED DL7 turns off, indicating the end of the memorization procedure.
With DL7 off, MASTER Wi-Fi FR is ready to work.
- Push a button of a remote control. The LED DL7 turns on green for a moment, indicating
recognition of a valid code. After 2 second led DL5 turns on for a moment, at the same
time total opening is ordered.
Note: If, when pushing a button on the remote control, LED DL7 turns red for a moment,
this means that the code is not in the memory and you must therefore perform the
memorization procedure again.
PROCEDURE TO DELETE ALL REMOTE CONTROL CODES
- Position jumper JP2 as shown here:
- Push and release button PROG RX on the MASTER Wi-Fi. LED DL7 emits a red light for 0.5
sec. and then turns off, indicating successful removal of codes.
- Position jumper JP2 as shown here:
- LED DL7 begins flashing red/green, indicating that the memory is empty.
Note: Jumper JP2 during normal operation must be positioned as shown here:
FULL MEMORY SIGNAL
If, pushing and holding button PROG RX on the MASTER Wi-Fi for at least 3 seconds, upon
release LED DL7 flashes green 6 times, this means that the memory is full (maximum 100
codes).

TECHNICAL SPECIFICATIONS

- POWER
- APPLICABLE TENSION ON CONTACT J4
- APPLICABLE TENSION ON CONTACT J2
- ABSORPTION AT REST
- MAXIMUM ABSORPTION
- WORKING TEMPERATURE
- SIZE
- WEIGHT
SAFETY DEVICES AND SIGNALING RADIO FREQUENCY SIGNAL TECHNICAL
INFORMATION
- FREQUENCY
- SENSITIVITY
- EMITTING POWER
- MODULATION TYPE
- RANGE
COMMAND ACTIVATION RADIO FREQUENCY SIGNAL TECHNICAL INFORMATION
- FREQUENCY
- SENSITIVITY
- MODULATION TYPE
- RANGE
Code ACG6052
Code ACG6054
To download the video of the installation write the following address
Code ACG6056
in your browser, or, read the QR code with your smartphone:
Code ACG6058
23
12/24 Vac/dc
120/220/230V 50/60Hz
12/24V ac/dc
40 mA
100 mA
-20°C ÷ +60°C
125x55x28 mm
0,090 kg
868,3 MHz
-108 dBm
<25 mW
FSK
20 m in open spaces
433,92 MHz
-107 dBm
OOK
100 m in open spaces with antenna
G