Technical Specifications; Accessories - RIB KIT PREMIER 24V Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

G G
B B
T
ECHNICAL SPECIFICATIONS
- Humidity
- Power supply voltage
- Frequency
- Battery power supply
- Weight without battery
- Level of protection of the wall mounted box
- Volume of wall box
- Transformer power
- Maximum absorption
- Interruptions in electricity supply
- Maximum power of gate open indicator 12Vdc 3W (equivalent to 1
- Maximum charge of blinker output
- Current available for photocells and accessories 1A ±15%
- Current available on radio connector

ACCESSORIES -

B
ATTERY CHARGE CARD
The time needed to charge completely the 12Vdc 2,2Ah batteries (n° 2
batteries connected in series, optional cod. ACG9515), upon first
installation, is 24 hours, with a charging current of 0.03A.
WORKING WITH BATTERIES - STATE OF BATTERY INDICATOR
(SIGNAL - COM)
Should you need to have an indication about the leaf position, the
output SIGNAL - COM can be connected to a 12Vdc bulb of 3W
maximum. It is turned ON when the gate is open or partially open, it is
turned OFF only when the gate is completely closed.
Besides, in case the operator is equipped with batteries, the same
indicator will emit 2 brief flashes followed by a pause of 2 seconds if the
gate is in closed position during a blackout, indicating that the operator
is powered by the batteries. The functioning of the gate is guaranteed
till a minimum of a charge level of approximately 20V. A lower charge
will stop the gate and the indicator will flash continuously to signal that
the batteries are too low.
< 95% without condensation
230V~ ±10% (120V/60Hz
upon request)
50/60 Hz
20-24,5Vdc
kg 3,0
IP55
33x24,2x12,4
130VA - primary 230Vac -
Secondary 18Vac
25 mA
100ms
bulb of 3W or 5 LED with
serial resistance of 2,2 k )
24Vdc 20W
200mA
For the connections and the technical data of the optional equipments follow the relevant
handbooks.
TECHNICAL RADIO SPECIFICATIONS (model PK2 24V CRX)
- Reception frequency
- Impedance
- Sensitivity
- Time of excitation
- Time of discharge
ALL THE INPUTS TO THE CONTROL BOARD, LIKE COMMAND
PUSH BUTTONS, PHOTOCELLS, SAFETY STRIPS, MUST BE
CLEAN CONTACTS.
Only when the main AC voltage returns, the indicator will turn off, all the
gate controls will be restored and the batteries will be recharged.
WE RECOMMEND NOT TO OVERLOAD THE INDICATOR OUTPUT
(SIGNAL - COM) OTHERWISE THE GATE FUNCTIONING COULD BE
COMPROMISED OR THE CONTROL BOARD COULD BE DAMAGED.
During this phase the safety devices are active.
B
ATTERY
Battery 2,2Ah 12V
433,92MHz
52 OHM
>2,24 V
300ms
300ms
cod. ACG4661
code ACG9515

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ad00743Ad00744

Table des Matières