RHOSS MICROSYSTEM TCAEY Série Mode D'emploi page 90

Refroidisseurs d'eau et pompes à chaleur réversibles avec groupe de pompage; refroidisseurs d'eau et pompes à chaleur réversibles avec groupe de pompage et d'accumulation intégrés
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Model TCAEY (400-3-50)
Nominal cooling capacity (*)
Nominal cooling capacity (**)
E.E.R. (*)
E.E.R. (**)
E.S.E.E.R.
E.S.E.E.R.+
Sound pressure (***)
Sound power level (****)
Scroll/step compressor
Fans
Exchanger water contents
Water side exchanger nominal water flow (*)
Motor-driven pump useful static pressure (P/L installation) (*)
Motor-driven pump useful static pressure (T/H installation) (*)
Water tank contents (T and H installation)
R410A refrigerant charge
Polyester oil charge
Electrical data
Absorbed power (*) (●)
Absorbed power (**) (●)
Motor-driven pump absorbed power (P and T installation)
Motor-driven pump absorbed power (L and H installation)
Electrical power supply
Auxiliary power supply
Nominal current (*) (■)
Nominal current (**) (■)
Maximum current (■)
Starting current
Motor-driven pump absorbed current (P and T installation)
Motor-driven pump absorbed current (L and H installation)
Dimensions
Width (L)
Height (H) P and L installation
Height (H) T and H installation
Depth (P)
Water connections
(*) In the following conditions: condenser input
air temperature 35°C; chilled water
temperature 7°C; temperature differential at
evaporator 5°C.
(**) Sound pressure level in dB(A), measured at
a distance of 5 m from the unit, with a
directionality factor of 2.
(***) Sound power level in dB(A) on the basis of
measurements made in compliance with the
UNI EN-ISO 3744 standard and Eurovent 8/1.
ALLEGATI / ENCOLSED DOCUMENTS / ANNEXES / ANLAGEN / ANEXOS
(■) Current absorbed without motor-driven
pump.
(●) Power absorbed without motor-driven pump.
N.B.:
The calculation of the E.E.R. and C.O.P. does
not take the pump absorption into account.
To obtain the total power and the total currents,
add the relative power and current values
absorbed by the motor-driven pumps.
90
107
109
kW
6,9
8,8
kW
9,3
12,2
2,58
2,66
3,54
3,56
2,77
3,16
3,07
3,50
dB(A)
47
47
dB(A)
69
69
No.
1/1
1/1
No. x kW
1 x 0.14
2 x 0.14
l
0,45
0,58
l/h
1213
1582
kPa
55/86
85
kPa
54/73
78
l
19
30
See serial No. plate
See compressor plate
kW
2,67
3,32
kW
2,61
3,43
kW
0,18
0,29
kW
0,29
-
V-ph-Hz
400-3-50
V-ph-Hz
230-1-50
A
3,0
4,8
A
3,5
5,3
A
7,3
8,6
A
35
48
A
1,12
1,40
A
1,40
-
mm
990
990
mm
905
1085
mm
905
1290
mm
380
380
Ø
1"G
1"G
H
111
11,1
15,5
2,62
3,54
3,15
3,49
47
69
1/1
2 x 0.14
0,76
1995
75
73
30
4,25
4,39
0,29
-
6,5
7,2
11,4
64
1,40
-
990
1085
1290
380
1"G
L

Publicité

Table des Matières