Cleaning And Maintenance - EUROM PAC 12.2 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
The dehumidification extracts more water from the air. This is why we recommend connecting
a hose to the water drainage – constant B during dehumidification and leading it to a (lower)
water drainage point (constant – drainage).
If the water pump is defective but you would still wish to use the device, connect a hose for
constant drainage to one of the water drainage points. It will be possible for the device to work
normally.
Safety
The PAC12.2 / 14 is fitted with an overheating safeguard that switches the unit off if it
overheats. If this should occur, you must remove the plug from the socket and leave the
PAC12.2 / 14 to cool for at least 30 minutes. Remove the cause of overheating - has the device
been (partially) covered? Is it too close to a wall or another obstacle, preventing it sucking in or
dispelling sufficient air?
You can then use the device normally again but keep an eye on it for the first 30 minutes to
ensure there are no further problems. If the device is showing signs of problems or the
overheating recurs, even though there is no obvious assignable cause, ask your supplier or a
recognised electrician to check/repair the unit.

CLEANING AND MAINTENANCE

Note! Before cleaning or carrying out maintenance work on the air conditioning unit, always
switch off and remove the plug from the socket! Regular cleaning is vital in order to keep the
unit in good working order!
Cleaning the housing
Use a soft, damp cloth to wipe the housing.
Never use aggressive cleaning products, petrol, detergent, chemically-impregnated cloths or
other cleaning solutions. These could damage the housing. Never spray the unit and ensure
that water never penetrates the device! Dry the unit with a soft cloth.
Cleaning the filters
Clean the filters once every two weeks; a unit with dirty filters will never work properly.
 Open the grill of the air inlet and remove the filter.
 Clean the filter in lukewarm water (max. 40°C), possibly with a neutral cleaning agent. Allow
the filter to dry thoroughly in the shade.
 Put the filter back into the grill and the grill back into the device.
Take care! Never use the air conditioning unit without the filters!
End of season cleaning
If the device is to be stored for a long period, you must take the following measures!
 Open the water drainage point (11) and allow the condensed water to drain out completely.
Run the unit for a few hours on fan function so that the unit is completely dry inside.
Then switch the air conditioning unit off, remove the plug from the socket and:
 Clean the filter and either put it back or replace it.
 unscrew the waste pipe from the device in order to prevent damage;
 pack the air conditioning unit in its original packaging or in a plastic bag and place in a dry
place for storage, not smaller than 10m². Never place a heavy object on the unit.